Manual MCS-64 Ethernet

Page 3

Linearity

< 0.002 % FS

Excitation

5 V DC, load cells 100-2 000 Ohm, 6 wire technique

Analogue input range

±2.2 mV/V (bipolar)

Minimum input per vsi

0.05

μV per interval non approved

Resolution

±260 000 counts , ±18-Bit-A/D convertor

Conversion rate

2400 measurements per second intern

Digital Filter

FIR Filter 2.5 ... 19.7 Hz or IIR Filter 0.25 ... 18 Hz; programmable in 8 steps each

Calibration

software calibration and set up

Computer interface intern

RS485/RS422, full duplex, 115 200 Baud, bus capability up to 64 devices

Weighing functions

zero, gross, tare, net, filter etc.

Inputs

4 opto-isolated inputs, 10 ... 30 V DC max. 3 mA

Outputs

4 OC outputs, < 35 V DC, 500 mA

Temperature effects

on zero

5 ppm/°K typ.; max. < 10 ppm/°K

on span

4 ppm/°K typ.; max. < 8 ppm/°K

Temperature range

–10 °C to +50 °C (operating); –30 °C to +80 °C (storage)

Enclosure

Aluminium, protection IP40

Dimensions

80 x 23 x 100 mm, with two M3 fixing screws for mounting on boards MB89.1/2/3/4

Power supply

12 ... 24 V DC ±10 %, < 60 mA,(reversed voltage, burst and ESD protected)

Power consumption

1,5 W max.

EMC

CE 73/23/EEC; 93/98/EEC and 89/336/EEC

Computer interface via Service Port MB 89.1

RS232C, 115 200 Baud

Vibration

withstands 1.0 G operational; 2.5 G non-operational

LDM 88.1 Specifications

Weighing Processor LDM 88.1

LDM 88.1

The digital weighing processor LDM 88.1 is a load cell
digitizing unit for precise measuring of loads in motion.

± 18 bit resolution (±260 000 d)

Excitation 5 V DC / 50 mA

2 400 Measurements/s internal,
600 Measurements/s external

mV/V calibration

4 DI’s

4 DO’s

RS 485 bus, 115.2 kBaud

Digital Filter (FIR and IIR)

for static or dynamic weighing
processes

3 Firmware versions

Load Cell

Low-Pass

Filter

Digital Filter

IIR- / FIR

ADC

- Net
- Gros
- Average
- Dose

Digital
Output /
Setpoint
1 ... 4

Digital
Input
1 ... 4

RS

485

/

230

kBaud

binary

format

LDM 88.1

Remote Control Output

Start Filling Cycle

Trigger Signal