beautypg.com

Flintec MCS-64 ModbusOnEthernet User Manual

Page 10

background image

Page

10

Manual MSC-64: Modbus on Ethernet

4.1.2 LDM Register Map

The register map for each LDM.

LDM overview

Register Type

Size

Access

Function

2000 – 201F

Float

08 * 2

R

/W

Data in Float Format

2020 – 205F

Int32

16 * 2

R

/W

Data in Integer Format

2060 – 207F

Int16

08 * 1

RW

Control/Status functions

2080 – 20FF

(reserved)

2100 – 2FFF

-

-

R/W

Parameter pages

Data in Float Format

Register Type Size Access Data

in

Float

Format

2000 Float

2 R

Gross

weight

2002 Float

2 R

Net

Weight

2004 Float

2 R/W Tare

2006 Float

2 R

Dosed

weight

2008 Float

2 R

Average

weight

Data in Integer Format

Register

Type

Size

Access

Data in Integer Format

2020 Int32

2 R

Gross

weight

2022 Int32

2 R

Net

Weight

2024 Int32

2 R/W Tare

2026 Int32

2 R

Dosed

weight

2028 Int32

2 R

Average

weight

202A Int32

2 R

A/D

sample

202C Int32

2 R

Device

ID

202E Int32

2 R

FW

Version

2030 Int32

2 R

Device

Status

2032 Int32

2 R

ADC

Reference

Control/Status Functions

Register Type Size Access Control/Status functions
2060

Int16

1

R

Measurement Qualifier Values:

$0001 - Under range
$0002 - Over range
$0004 - Not within Zero range (not yet implemented, zero)
$0008 - Exactly zero
$0010 - No motion, still stand, steady state
$0020 - Tare set
$0040 - Preset tare (0=tare is measured, 1=tare is set by user)
$0080 - Invalid weighing (wire-break, A/D ref. out of range)
$0100 - Set-point 0 (source>limit)
$0200 - Set-point 1
$0400 - Set-point 2
$0800 - Set-point 3
$1000 - Filling in progress
$2000 - Filling has completed
$4000 - Average ready
$8000 - Cold start