Connecting adaptec-x to an alarm siren, Benefi ts of using adaptec-x with alarm siren, Wiring diagrams – FingerTec AdapTec-X User Manual
Page 9

9
Remark:
• Set Auto Alarm in terminal to N.
• Menu > Options > Sys Opt > Adv
Opt > Auto Alarm > N.
Connection
Points
Siren Mute
Button
AdapTec-X
Regulated Battery
Tamper Siren EM +12 OV Siren Exit
OV
Data
Input
SW Out Lock Out
Mute SW
0V
+14.5V
0V
12V
D1
D0
GND
12V
ALM+
ALM
_
Alarm
Siren
+ ---
CONNECTING ADAPTEC-X TO AN ALARM SIREN
For all FingerTec door access control models, there is a security
button behind the terminal. During normal operation, the secu-
rity button is compressed and once the terminal is dismantled,
the button will be released and a
“System broken”
message will
appear onscreen.
During the release of the button, the terminal will output an alarm signal. How-
ever, no alarm sound will be emitted if the terminal is not equipped with an
external siren.To use the siren feature, we recommend that you install an ad-
ditional alarm siren and connect it to the FingerTec terminals.
Benefi ts of Using AdapTec-X with Alarm Siren
We recommend that you install a terminal along with AdapTec-X if you plan
to use the alarm siren. In AdapTec-X, an additional port is readily built to re-
ceive the alarm signal from the FingerTec terminals. AdapTec-X has an output
of DC12V and it is suitable for use with an alarm siren that has the same power
input. You do not need to source an additional DC12V power supply for this
purpose. Furthermore, AdapTec-X comes with a
“Siren Mute”
button where
you can press the button to deactivate the alarm siren when required.
WIRING DIAGRAMS
3
ALARM SIREN •
AC900, R2, Kadex, m-Kadex, H2i and Face ID 3