Rs485 single connection, Rs485 network connection – FingerTec AC100 Plus User Manual
Page 33

33
RS232 cable
RS232/RS485
RS485
PC
Converter Plug AC100 / AC100 Plus
Comm Opt
u
4
RS232 Yes
4RS485 Yes
Note
When RS485 func-
tion is enabled, the
Ethernet will be
disabled.
Note
The RS232/ 485
converter is an op-
tional component.
Comm Opt
u
4
RS232 Yes
4RS485 Yes
Note
When the RS485
function is ena-
bled, the Ethernet
will be disabled.
RX+
RX-
RS485 Single Connection
1. Setup of RS485
Access Menu, select “Options” > “Comm. Opt”
> “RS485”, select “Yes” to enable RS485
function.
2. Turn off the reader.
3. Plug the RS485 cable extender to the connector. Connect another
end of the cable to the RS232/485 data converter.
4. Connect the RS485 data converter to the RS232 port of PC.
5. Turn the power on.
RS485 Network Connection
1. Setup of RS485
Access Menu, select “Options” > “Comm. Opt”
> “RS485”, select “Yes” to enable RS485
function.
2. Turn off the reader.
3. Plug the RS485 cable extender to the RS232/485 port on the Power Controller, and an-
other end of the cable to the RS232/485 network.