SYSTEM
System Settings
THRESHOLD
Threshold is the level of the fingerprint scanner’s sensitivity. Threshold determines how
many percent of minutiae points on a fingerprint template will be read by the system.
The higher the threshold level, more points are being read, more restricted the system.
Configure the threshold for 1:1 and 1:N methods.
For 1:1, the range is from 0-50 and the recommended value is 15.
For 1:N, the range is from 0-50 and the recommended value is 5.
Press Menu > System > System > Threshold (1:1) or Threshold (1:N) > Determine the
Level > OK to Save
DATE FORMAT
The date format can differ based on countries for example in Malaysia, the date-month-
year format is used while in America, the month comes first. Choose your date format
according to your preference. The default format is dd-mm-yy. Press Menu > System >
Date Format > Select Format > Ok to Save
SOUND OF KEYBOARD
The terminals emit sound when you press any of its buttons. To turn on/off the keypad
sound:
Press Menu > System > Keybeep > On/Off >Ok to Save
VOICE
The terminal has certain voice commands to guide users during enrolment and to no-
tify users during verification. Press Menu > System > Voice > On/Off > OK to save
ALGORITHM VERSION
Get the terminal’s algorithm version here. Press Menu > System icon > System > Alg
Version > View the Version > Ok to Save.
RECHECK MIN
Once you have inserted a value, eg: 1, when a user checks in at 10:01, his time will be
adjusted to 10:00. The maximum value is . When you enter 5, a user is given 5 minutes
leeway time in his attendance.
LOG ALERT
When the log storage is at a certain level, the user/administrator needs to be alerted to
avoid underperformance of terminal. The recommended value is . Menu > System >
System Settings> Log Alert > Input your value > Save