beautypg.com

Configuration parameters table 1, Table 2 – EVCO EC7102 User Manual

Page 5

background image

5

2 '01

COD. PARAMETER

DESCRIPTION

MIN.

MAX.

U.M.

ST.

t 0

"Status 1" and "Status 3" time base

0=sec.:dec.; 1=min.:sec.; 2=hours:min.

0

2

----

0

t 1

E 1 switching mode

0=rising (N.C. cont.); 1=falling (N.O. cont.)

0

1

----

0

t 2

E 2 switching mode

0=rising (N.C. cont.); 1=falling (N.O. cont.)

0

1

----

0

t 3

signalling buzzer functioning during the "Status 4" 0=excluded; 1=continuous; 2=intermittent

0

2

----

0

t 4

modality of "Start" input enabling

0=UP or E 1; 1=UP; 2=E 1

0

2

----

0

t 5

modality of "Stop" input enabling

0=DOWN or E 1; 1=DOWN; 2=E 1

0

2

----

0

t 6

count mode

0=countdown; 1=countup

0

1

----

0

t 7

count continuation function

0=NO; 1=YES

0

1

----

0

(1)

t 8

count holding

0

2

----

0

t10

"Status 2" time base

0=sec.:dec.; 1=min.:sec.; 2=hours:min.

0

2

----

0

t11

"Stato 1" lenght

see TABLE 1

0

t12

output 1 activated ON or OFF

0=ON; 1=OFF

0

1

----

0

t20

"Stato 3" lenght

see TABLE 1

0

t21

output 2 activated ON or OFF

0=ON; 1=OFF

0

1

----

0

(2)

t22

end of "Status 4" modality

0

2

----

0

t23

"Status 4" time base

0=sec.:dec.; 1=min.:sec.; 2=hours:min.

0

1

----

0

t24

"Stato 4" lenght

see TABLE 1

0

t25

outputs configuration

see TABLE 2

0

t31

count showing during the "Status 1"

0=NO; 1=YES

0

1

----

0

t32

count showing during the "Status 2"

0=NO; 1=YES

0

1

----

0

t33

count showing during the "Status 3"

0=NO; 1=YES

0

1

----

0

t34

count showing during the "Status 4"

0=NO; 1=YES

0

1

----

0

L

NETWORK CONNECTION

L 1

instrument address

1

15

----

1

L 2

instrument group

0

7

----

0

NOTES

(1) = see "Count holding" function.
(2) = the "Status 4" can end according to one of the following modality:

- for a "Stop" input ("t22"=0)
- for a "Start" or "Stop" input ("t22"=1)
- for a "Stop" input or at the end of the established time ("t22"=2).

CONFIGURATION PARAMETERS

TABLE 1

"Status ..."

range of timer setting

time base

resolution

display end of scale

sec.:dec.

00:10

99:90

min.:sec.

00:01

99:59

hours:min.

00:01

99:59

TABLE 2

parameter "t25"

K1

K2

Notes

linked to

linked to

0

output 1

output 2

-

1

output 1

output 1

K 2=K 1

2

output 2

output 2

K 1=K 2