beautypg.com

Functioning – EVCO EC7102 User Manual

Page 2

background image

2

2 '01

FUNCTIONING

A complete cycle of counting has five status connected in cascade since, the end of one, automatically determines the passage to the following
one.

"Status 0" (dedicated parameters t 1, t 4, t 7, t8, t12, t21, t25):

At any reset or after a "Stop" input the instrument automatically moves to the "Status 0" (the modality that enables the "Stop" input can be established
with the parameter "t 5").
For all the length of this status on the display appear:

- the time to be counted during the "Status 2" if the parameter "t 6" has value 0
- the indication "00:00" if the parameter "t 6" has value 1

the lighting indicators located in the middle of the display are lighted, the outputs are deactivated.
A "Start" input during this status forces the instrument to the "Status 1" (the modality that enables the "Start" input can be established with the
parameter "t 4").

"Status 1" (dedicated parameters t 0, t 2, t 5, t 6, t 8, t11, t12, t21, t25, t31):

The "Status 1" permits to delay the activation of the following status.
During this status the instrument counts the time established with the parameter "t11", according to the time base established with the parameter
"t 0".
For all the length of this status on the display appear:

- the time to be counted in the following status if the parameters "t 6" and "t31" have value 0
- the indication "00:00" if the parameter "t 6" has value 1 and the parameter "t31" has value 0
- the countdown of the time to be counted in this status if the parameter "t 6" has value 0 and the parameter "t31" has value 1
- the count up of the time to be counted in this status if the parameters "t 6" and "t31" have value 1

the lighting indicators located in the middle of the display alternately flash, the outputs are not activated.
At the end of the established time the "Status 1" ends and the device automatically moves to the "Status 2".
NOTES:

- one "Stop" input during this status forces the instrument to the "Status 0", on the display remains the indication showed during

the "Status 0".

"Status 2" (dedicated parameters t 2, t 5, t 6, t 8, t10, t12, t21, t25, t32):

During this status the instrument counts the time established with the keys located on the frontal panel, according to the time base established
with the parameter "t10".
To set the time to be counted during the "Status 2" push and release the key

: the most important side of the display flashes; operate

with the keys

or

within 4 seconds since the first pressure on key

to modify its value.

To set the value of the least important side of the display push and release the key

during the flashing of the most important side of the

display: the least important side of the display flashes; operate with the keys

or

within 4 seconds since the second pressure on key

to modify its value.

To leave the procedure of setting of the time to be counted during the "Status 2" wait 4 seconds without operate on the keys (time-out exit)
or push and release for a third time the key

.

For all the length of this status on the display appear:

- the time to be counted in this status if the parameters "t 6" and "t32" have value 0
- the indication "00:00" if the parameter "t 6" has value 1 and the parameter "t32" has value 0
- the countdown of the time to be counted in this status if the parameter "t 6" has value 0 and the parameter "t32" has value 1
- the count up of the time to be counted in this status if the parameters "t 6" and "t32" have value 1

the lighting indicators located in the middle of the display flash at the same time, the output 1 is activated.
At the end of the established time the "Status 2" ends and the device automatically moves to the "Status 3".
NOTES:

- if the parameter "t12" has value 1, the output 1 always is activated except during this status
- if the parameter "t25" has value 2, the output 1 gets activated/deactivated with the same modality of the output 2, respecting the

parameter "t12" only

- one "Stop" input during this status forces the instrument to the "Status 0", on the display remains the indication showed during

the "Status 0".