EVCO EC6295S201 User Manual

Page 2

background image

• press

or

for selecting

• press

6.3 Second evaporator temperature showing

If you have to show the second evaporator temperature:

• gain access the additional functions

• press

or

for selecting

• press

6.4 Temperature alarm storage

If you have to show the temperature the instrument has stored

during the lower temperature alarm:

• gain access the additional functions

• press

or

for selecting

(3)

• press

If you have to show the temperature the instrument has stored

during the upper temperature alarm:

• gain access the additional functions

• press

or

for selecting

(4)

• press

If you have to erase the temperature the instrument has stored

during the lower or upper temperature alarm:

• gain access the additional functions

• press

or

for selecting

or

• press

for 4 s

: the instrument

will show

(3)

unless the parameter A8 has value 1 or 3, the label AL will not be showed

(4)

unless the parameter A8 has value 2 or 3, the label AH will not be showed.

7

SIGNALS

7.1 Signals

4

WORKING SETPOINT

4.1 How to set the working setpoint

If you have to modify the working setpoint value:

• press

and

or

(1)

(2)

(1)

you can set the working setpoint between the limits you have set with the param-

eters r1 and r2

(2)

unless the parameter r5 has value 0, you can not modify the working setpoint.

5

CONFIGURATION PARAMETERS

5.1 How to set the configuration parameters

Configuration parameters are arranged on two levels.

If you have to gain access the first level:

• press

and

for 4 s

: the instrument

will show

If you have to select a parameter:

• press

or

If you have to modify the value of the parameter:

• press

and

or

If you have to gain access the second level:

• gain access the first level

• press

or

for selecting

• press

and

or

for setting “ -19 “

• press

and

for 4 s

: the instrument

will show

If you have to quit the procedure:

• press

and

for 4 s

or do not op-

erate for about 60 s.

6

ADDITIONAL FUNCTIONS

6.1 How to gain access the additional functions

If you have to gain access the additional functions:

• press

for 2 s

: the instrument

will show

If you have to quit the procedure:

• press

or

as long as the instrument

shows the cabinet tem-

perature or do not oper-

ate for about 30 s.

6.2 First evaporator temperature showing

If you have to show the first evaporator temperature:

• gain access the additional functions

LED

MEANING

Compressor LED

if it is lighted, the compressor will be ON

if it flashes, a compressor delay will be running (look at the parameters

C0, C1, C2, C4, n1 and n4)

(15) the instrument will automatically verify the maximum value of the parameter; it always has to be lower than the value you have set with the parameter i4

(16) when there is 1 min to the end of the time you have set with the parameter, the cabinet light will be turned OFF just for 1 s; press

during the time you have set with the

parameter to turn the cabinet light ON and to exclude the function, press

again before the end of the time you have set with the parameter to recover the function

(if the remaining time of the parameter is higher than 1 min, the time will be forced at 1 min and the cabinet light will be turned OFF just for 1 s)

(17) do not set more instruments as master

(18) the time between the master implements a control and the slave implements the same control is “n1 x n4”

(19) except the control turning ON and OFF; it will immediately be implemented

(20) if among the remote controls the slave has to implement there is the defrost activation, the parameter d5 will set a time you will have to add to the one you have set with the

parameters n1 and n4 (the slave will implement the control even if the conditions will not allow the master of activating the defrost); if the master is in the STAND-BY mode and

among the remote controls the slave has to implement there is not the turning ON and OFF, the slave will work with the local settings.

11

ELECTRICAL CONNECTION

11.1 Electrical connection

(21) short-circuit terminals 1 and 5 and/or 1 and 7 if you do not use the lock input and/or the compressor thermal protection

(22) the position of the probe for compressor thermal protection could compromise the insulation between low voltage and high voltage parts.