PARAM. MIN.
MAX. U.M.
1 INPUT
2 INPUTS
i5
0
4
- - - -
0
0
i6
0
1
- - - -
0
0
PARAM. MIN.
MAX. U.M.
1 INPUT
2 INPUTS
LA
1
247
- - - -
247
247
Lb
0
3
- - - -
2
2
LP
0
2
- - - -
2
2
(1)
the unit of measurement depends on parameter P2
(2)
set the parameters relative to the regulators appropriately after modification of parameter P2
(3)
the value depends on the type of functioning (1 with 1 measurement input and 3 with 2 measurement inputs)
(4)
the value depends on the type of functioning (2 with 1 measurement input and 4 with 2 measurement inputs)
(5)
ds = tenths of second
(6)
the buzzer and the acoustic output are activated before the conclusion of the cooking timer count (of the time established with the parameter c9), for the time established with parameter c4
(7)
if the cooking timer is interrupted (with the procedure given in paragraph 5.4 or by activation of the malfunction input), the duration of buzzer activation and of the acoustic output and the flashing duration
of the 00:00 indication will be 3 seconds
(8)
the parameter differential is 10 °C/18 °F
(9)
pressing the
key causes the associated effect.
DIGITAL INPUTS
effect caused by the activation of the multifunction input
0 = no effect
1 = START/INTERRUPTION OF THE COOKING TIMER - the activation of the input will cause the cooking timer to start and the successive activation will cause
its interruption
2 = CHAMBER LIGHT SWITCH-ON/OFF - the activation of the input will cause the chamber light to switch-on and the successive activation will cause its
switch-off
3 = BUZZER, ACOUSTIC OUTPUT AND BUZZER OUTPUT DEACTIVATION - the activation of the input will cause deactivation of the buzzer, the acoustic
output and the buzzer output (activate the input again to deactivate these utilities again)
4 = STEAM INJECTION - in this case:
• if t0 = 0, the activation of the input causes the injection of steam for the time established with parameter t2 or for the entire duration that the key is
pressed (parameter t1 establishes the minimum time that can pass between the two successive injections) (9)
• if t0 = 1, the activation of the input will enable automatic steam injection (in cyclical mode; parameter t2 establishes the duration of the switch-on
of the injector and parameter t1 establishes the duration of switch-off) until the input is activated again (9)
type of contact of the multifunction input
0 = NO (input active with closed contact)
1 = NC (input active with open contact)
SERIAL NETWORK (MODBUS)
instrument address
baud rate
0 = 2.400 baud
1 = 4.800 baud
2 = 9.600 baud
3 = 19.200 baud
parity
0 = none (no parity)
1 = odd
2 = even