D.A.S. AUDIO S.A. (Valencia) MADE IN SPAIN
SIGNAL INPUT
IDENTIFY/COMMS
THROW
LOOP THRU
LONG
MID
SHORT
ON/PROTECT
SIGNAL/
LIMIT
NUMBER OF UNITS
16
8
4
2
12
6
3
1
20
CAUTION
DO NOT EXPOSE THIS EQUIPMENT
TO RAIN OR MOISTURE
RISK OF ELECTRIC SHOCK
DO NOT OPEN
N1918
IN
OUT
default factory
settings
NUMBER OF UNITS
UNIT NAME
STAGE / VENUE
THROW
115/230 V~ 50/60Hz 620W
AC INPUT
MAX. 5@230V / 2@115V UNITS AERO 20A
AC OUTPUT
ID DASNET
step 1
press Throw
knob
Step 2
turn on the
PowerCon
Preset changes are bidirectional so if a preset is changed on the software it will be also changed
on the cabinet. And vice versa, a change on the cabinet will be shown as well on the software.
IMPORTANT: all DASnet control parameters (gain, delay, presets, mute, solo...etc) are stored on
the micro controller included in the amplifier. This means that after switching off the system all values
of the parameters will remain the same in memory for the next time the system is switched on.
IMPORTANT: when the user is not sure about the internal settings in the micro controller (delay,
gain etc) the best thing is to do a factory settings reset. Factory settings puts all the parameters
at zero. Device name will remain the same (in this case aero 20A-1).
Factory settings reset can be done via software: (check that gain and delay are set up at zero)
IMPORTANT: The default or factory settings on the aero 40A are:
Number of Units: 1 Unit
Throw: Mid Throw
But also physically by pressing the preset throw knob (holding during a few seconds) while
powering the cabinet.