API Functions
aaReadWithStatus
aaReadWithStatus
Reads serial data and status from a device.
aaReadWithStatus(Dev,Cnt,Buf)
int Dev
Device number
int Cnt
Max number of bytes that can
be read
unsigned int *Buf
Buffer to store the data and
status. The low byte of each
array element in Buf contains
the data byte, and the high byte
contains the status for that data
byte. The status may be 0
indicating no error, or any
combination of the following
flags:
ERR_PARITY
parity error
ERR_OVRRUN
receiver over
run error
ERR_FRAME
framing error
ERR_BREAK
break
int: Number of bytes read
if successful
0
if no data available to be
read
ERR_DEV
if device number out of
range
ERR_NOTOPEN
if device not open for receive
The Cnt parameter should not be greater than the
number of array elements in the Buf receive buffer.
Function
Purpose
Call
Return
Warning
aaReconfigure
Reconfigures a device’s communications parameters.
aa
R
econfigure(
Dev,Baud,Parity,DataBits,StopBits,FlowCtl,Detect
En
);
int dev;
Device Number
unsigned char Baud
One of the baud rate flags
defined in
API.H
.
unsigned char Parity
One of:
COM_PAR_NONE,
COM_PAR_EVEN,
COM_PAR_ODD
.
unsigned char DataBits
One of
COM_DATABIT_7,
COM_DATABIT_8
.
unsigned char StopBits
One of
COM_STOPBIT_1,
COM_STOPBIT_2
.
unsigned int FlowCtl
Flow control flag, can be
COM_FLOW_NONE
or any
combination of:
COM_FLOW_IS,
COM_FLOW_OS,
COM_FLOW_IH,
COM_FLOW_OH,
COM_FLOW_OXANY.
unsigned int DetectEn
Detection enable flags, can be
any combination of the
following:
COM_DEN_NONE
No error
detection
enabled
COM_DEN_
RDA
Enable Rx
data
available
detection
COM_DEN_MDM
Enable
modem
input
(
DSR
,
CD
, or
CTS
)
change
detection
int:
NO_ERR
if successful
ERR_DEV
if device number out of range
ERR_BAUDRATE
if invalid baud rate flag
Function
Purpose
Call
Return