FLUKE 900 SERVICE MANUAL
Seiftest
Tests 0,47 and SO are not automatically run during the poweran selftest, but can be nin by
themselves explicitly. This is also the case for a group of tests known as "engineering" or
"extended" tests which are designated Exx as follows:
E60
WALK SIZELEDS
E61
TEST MEMORY
E62
WALK MONLEDS
E63
UPDATE_VCC_UM
E64
SHAD ADDR
E70
KEY CLOSURE
E71
DISP RAM
E74
DISP CHAR SET
E75
CART_SLFT
E76
TEST C ENG
E77
ACT_CROSS
E78
TRG CROSS
E79
FRQ_CROSS
E80
FLT_CROSS
2 Flag Results
Flags may ^pear on lines 3 and 4 of the general results screen. A 0 means "OK" and a 1
means "fault". At the present time, only the first row is used.
BYTEO
I
0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
1 1 1 1 1 1 1 1
BIT: 76543210
BYTEl
BYTE2
I
I
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
BYTE3
I
0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
BYTEO: Indicates DRAM chip which failed memory test
B7: U86
B6: U82
B5: U87
B4: U83
B3: U88
B2:U84
Bl: U89
BO: U85
3-3