6-3. IIM CASE OF DIFFICULTY

The

problems

described

in

this

table

are

failures

caused,

in

general,

by

improper

operation

or

connection

of

the

transceiver,

not

by defective components. Examine and check according to the following table.

Symptom

Probable cause

Corrective action

Indicators do not light and no receiver noise is
heard when the POWER switch is turned on.

1. Bad power cable or connections.

2. Blown power supply fuse.

1. Check cables and connections.

2. Check for the cause of the blown fuse and

replace the fuse.

No sound from the speaker. No signal can be

received.

1. Squelch is closed.

2. With the TSU-6: CTCSS is operating.

1. Turn the SQL control counterclockwise.

2. Press the TONE/T.ALT key to turn off the

CTCSS.

No transmitter output.

1. Microphone jack is not plugged in.

2. Poor antenna connection.

1. Plug jack in.

2. Connect antenna securely.

Weak signal cannot be received.

Poor antenna connection.

Connect antenna securely.

Display is dark.

1. Power voltage is low.

2. The DIM key had been pressed.

1. Check voltage for 13.8 VDC ±15%.

2. Press the F key and the LOW/DIM key.

No control works.

LOCK is ON.

Set the Microphone Lock key to OFF position.

Memory cannot be backed up.

Backup battery voltage is low.

See Microprocessor memory back-up page
21.

36