beautypg.com

3. keyboard unit test functions, Mz3500 – Sharp MZ-3500 User Manual

Page 95

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

MZ3500

SUB CPU CHECKER FLOW CHART 2/3

SUB CPU CHECKER FLOW CHART 3/3

Set th* i*mef to 23 hour»,

59 fT^tnoie». 58 »«oodi

DecefT)b«r 31 ft

V on th« dtsp I

V on the d

V onthedtcp 1 Vo

KEY?

11-3. Keyboard unit test functions

1) Keyboard controller ROM test

(1) After power on in a normal condition, it starts to carry

out the ROM self-test.

If the alpha/symbol (LOCK) LED were to turn on, it

indicates a failure in KBC. If not, KBC is satisfactory.

/

Key self check functional specification (simplified

check)

2) Keyboard test

(1)

As the power is turned on with the "DEB" in depres­

sion, it goes into the keyboard self-test mode.

(2)

Depress key in a given sequence. If key is depressed in

a correct sequence, it makes the alpha/symbol (LOCK)

LED activated each time a key is pushed.

If the key was pushed in a wrong sequence or when a

failure is met in the key, it makes the LED blinked.-

(3)

It returns to the normal mode upon completion of

testing all keys. With this, the LED goes out.

(4) Observe the following key-in sequence to test.

) Turn the OP/PRO siwtch to the OP side.

i)

Turn on power while pushing the "DEB" key.

ii) Turn the PO/PRO which to the PRO side.

v) Push a key one at a time in accordance with the given

sequence.

102 -