SEWING

machíne

DIV. 20

MODEL 384. 15358

MECHANICAL ADJUSTMENT

NEEDLE SWING

TO CHECK:

ADJUST THE NEEDLE SWING ACCORDING TO THE FOLLOWING PROCEDURE, IF THE

NEEDLE BAR STARTS MOVING SIDEWAYS WHILE THE NEEDLE IS IN THE FABRIC AT

SEWING THE ZIGZAG PATTERN (WITH MAXIMUM ZIGZAG WIDTH).

ADJUSTMENT PROCEDURE:

1.

SET THE PATTERN SELECTOR DIAL WITH MAXIMUM ZIGZAG WIDTH, AND REMOVE

THE FRONT COVER (SEE PAGE 9).

2.

LOOSEN TWO SETSCREWS.

3.

ADJUST THE NEEDLE SWING BY TURNING THE HANDWHEEL, WHILE HOLDING THE

WORM SO AS NOT TO ROTATE IT, UNTIL THE NEEDLE SWING STARTS 2-3 MM

ABOVE THE NEEDLE PLATE AFTER THE NEEDLE HAS COME OUT OF THE RIGHT

SIDE OF THE NEEDLE HOLE.

4.

TIGHTEN TWO SETSCREWS.

5.

MOUNT THE FRONT COVER.

NOTE:

AFTER ADJUSTING THE NEEDLE SWING, CHECK THAT THE UPPER SHAFT

WORM AND GEAR ROTATE SMOOTHLY WITHOUT ANY BACKLASH

BETWEEN THEM.

14