Determine vent length – Kenmore 3405594 User Manual
Page 29
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
This laundry center may be converted
to exhaust out the right or left side. To
convert the laundry center, one of the
following kits MUST be used.
Side Exhaust Kit No. 3391335 (white)
Side Exhaust Kit No. 3391336 (almond)
Follow the instructions in the kit to
avoid operational and personal hazards.
These kits are available at your local
Sears store or Sears Service Center.
DETERMINE VENT LENGTH
Maximum Exhaust Lengths;
• Rear Exhaust. The maximum length
of the rear exhaust system depends
on the type of vent, the number of
elbows and the type of exhaust hood.
Refer to the chart below.
• Side Exhaust Side exhaust adds
a 90° turn inside the laundry center.
To determine maximum exhaust
length, add one 90° turn to the chart.
EXHAUST HOOD TYPE
Typical installations for left or right side
exhausting
Number of Maximum length of 4-incfi
90° Turns diameter rigid heavy metal vent.
0
Number of
90° Turns
0
36 ft.
34 ft.
29 ft.
26 ft.
24 ft.
20 ft.
16 ft.
14 ft.
12 ft.
Maximum length of 4-incfi
diameter flexible heavy metal vent.
22 ft.
16 ft.
8 ft.
21 ft.
15 ft.
7 ft.
16 ft.
10 ft.
2 ft.
NOTE: Avoid pushing the iaundry center
tightly against a wall. This can crush or
kink the vent. Use the straightest path you
can, where possibie, to avoid 90° turns.
29