Make certain this laundry center has the
correct burner for the type of gas in your
home. Burner information is located on
the rating plate in the door well of your
dryer, if this information does not agree
with the type of gas available, contact
your local Sears store or Sears Service
Center. Any change to the burner must
be made by a qualified installer.
■
Provide a gas supply of Vï-inch pipe
to your laundry center.
■
If your laundry center has been
converted to use L.P. gas, ^/e-inch
L.R-compatible copper tubing may be
used. If the total length of the supply
line Is more than 20 feet, use larger
pipe. Pipe joint compounds that resist
the action of L.P. gas must be used.
Do not use teflon tape.
■
This laundry center is equipped with its
own permanent, flexible gas connector,
design-certified by the American Gas
Association, for connecting the laundry
center to the gas supply line.
■ A combination of pipe fittings must
be used to connect the laundry center
to the existing gas line.
^/s-inch
male
threaded
connection
Va-inch
NPT
plugged
tapping
Reducer
or
connector
Vi-inch
gas
supply line
Gas
shut
off valve
• The gas supply must have a shut-off
valve. The valve should be in the same
room as the laundry center, within six
feet. The location should be easy to
reach for opening and closing the valve.
• A Vs-lnch NPT plugged tapping,
accessible for test gauge connection,
must be installed immediately upstream
of the gas supply connection to the
laundry center.
• To ensure proper combustion and
ventilation, the laundry center instal
lation should adhere to the minimum
recommended clearances. See page 18.
• For mobile home installation, see
page 19 for more instructions.
■ The laundry center must be discon
nected from the gas supply piping
system during any pressure testing
of that system at test pressures in
excess of ' h psig.