beautypg.com

Performance data sheet – Kenmore 106.511800 User Manual

Page 29

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

PERFORMANCE DATA SHEET

Water Filtration System

Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters)

System tested and certified by NSF internationai against NSF/ANSi
Standard 42 for the reduction of Chiorine Taste and Odor, and Particuiate
Ciass i*; and against NSF/ANSi Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The

concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the

permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Minimum %

Average %

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Reduction

Reduction

Chlorine Taste/Odor

50% reduction

2.0 mg/L

2.0 mg/L ± 10%

0.20 mg/L

97

97.2

Particulate Class 1*

85% reduction

7,300,000 #/mL

At least 10,000 particles/mL

75,000 #/mL"

99

99.4

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Minimum %

Average %

Reduction

Requirements

Influent

Concentration

Effluent

Reduction

Reduction

Live Cysts’

99.95%

160,000/L

50,000/L min.

54/L’

99.97

99.99

Asbestos

99%

87 MFL

10’to 10®fibers/L”

0.17 MFL

99

99

Lead: @ pH 6.5

0.010 mg/L

0.160 mg/L

0.15 mg/L± 10%

0.001 mg/L

99.4

99.4

Lead: @ pH 8.5

0.010 mg/L

0.140 mg/L

0.15 mg/L± 10%

0.005 mg/L

98.6

98.6

Lindane

0.0002 mg/L

0.0019 mg/L

0.002 mg/L± 10%

0.00002 mg/L

98.9

99

Toxaphene

0.003 mg/L

0.014 mg/L

0.015 mg/L± 10%

0.001 mg/L

93

93

Atrazine

0.003 mg/L

0.0094 mg/L

0.009 mg/L± 10%

0.0005 mg/L

94.5

94.7

2,4 - D

0.07 mg/L

0.220 mg/L

0.210 mg/L± 10%

0.028 mg/L

87.5

96.1

Test Parameters: pH —

Temp. = 68°F to 71.6°

7.5 + 0.5 unless otherwise noted. Flow — 0.5 gpm (1.9 Lpm). Pressure — 60 psig (413.7 kPa).

F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).

It is essential that operational, maintenance, and filter

replacement requirements be carried out for the product to

perform as advertised.

Use replacement filter P4RFWB, part #9930.

2011 suggested retail price of $49.99 U.S.A./$59.99

Canada. Prices are subject to change without notice.

Style 1 — When the water filter status display changes from

“GOOD” to “ORDER,” order a new filter. When the filter

indicator reads “REPLACE,” it is recommended that you

replace the filter.

Style 2 — When the filter indicator changes from green to

yellow, order a new filter. When the indicator changes from

yellow to red, it is recommended that you replace the filter.

Style 3 — When the filter indicator reads 10%, order a new

filter. When the indicator reads 0%, it is recommended that

you replace the filter.

After changing the water filter, flush the water system. See

“Water and Ice Dispensers.”

These contaminants are not necessarily in your water supply.

While testing was performed under standard laboratory

conditions, actual performance may vary.

The product is for cold water use only.

The water system must be installed in compliance with state

and local laws and regulations.

Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or

after the system. Systems certified for cyst reduction may be

used on disinfected waters that may contain filterable cysts.

Refer to the “Warranty” section for the Manufacturer’s

name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s

limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

3 0 - 1 2 0 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 378°C)

Service Flow Rate

0.5 gpm (1.9 Lpm) @ 60 psi

‘Class I particle size: >0.5 to <1 um

"Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

+Based on the use of Cryptosporidium parvum oocysts

ttpibers greater than 10 um in length

I NSF is a registered trademark of NSF International.

29