The AD-4406 has four Code memories (1 through 4). Each Code memory stores a set
of setpoints.
The data is stored in non-volatile memory, and is not lost even if power is turned off.
Memory number 0 is a temporary memory and the data is lost when power is turned
off.
The active code memory number can be changed by key switch, external control input,
or a command via the serial interface.
Changing the Code Memory Number by External Input
The code memory number can be changed by external input from OP-05 or OP-
08.
Set F14 and F15 to 18.
F13=18 : Inhibit reading EXT.2 and EXT.3 to
prevent unintentional reading when
switching the codes.
EXT2
EXT3
Memory Number
ON
ON
1
OFF
ON
2
ON
OFF
3
OFF
OFF
4
10. Code Memory