AD-4406 Weighing Indicator

Output of Accumulated Data

The accumulated data can be output to the serial interface.

Output by manual or automatic, and output data format is selected at F41 of the

F-function setting.

F41

Parameter

Manual/Automatic

Format

0

No output

* 1

Manual (initial setting)

2

Automatic

Fixed format

3

Manual

4

Automatic

Format 1 (selected at F34)

5

Manual

Accumulated data
output at
accumulated data
display

6

Automatic

Format 2 (selected at F35)

Step 1

Press the key assigned to operate the function to display totAL and the

accumulated data.

Step 2

If automatic output is set, the data is output once at that timing.

Step 3

If manual output, by pressing the F2 key while the accumulated data is displayed,

the data is output.

Fixed data format :