beautypg.com

Method of operation, Specificatons, Output derating characteristics – KEYENCE MS2 Series User Manual

Page 2: Dimensions, 2method of operation, Warranties and disclaimers

background image

2

Method of Operation

The display mode changes each time when the MODE switch is pressed.

Output current display

Load factor display

°

Peak current display

Output voltage display

• The MS2 Series is set to the output current display mode before shipment. It retains the display

mode that was used before the power was turned off.

• The maximum value for the peak current display mode is cleared when the power is turned off and

the display mode is changed.

• When the switch is held down for 3 seconds or more, the current mode is locked and cannot be

changed. To unlock the mode, hold down the switch again for 3 seconds or more.

Specificatons

Displays the output current down to 0.1 A.

Displays the load factor down to 1%.
When the load factor is over 100% , displays "FFP".

Displays the maximum value of the output current down to
0.1 A. The current and "PH" are displayed alternately.

Displays the output voltage down to 0.1 V.

Two holes only for OP-51624.

Two holes only for OP-51626.
The side mounting bracket can be attached to either sides.

MS2-H150

When front mounted

When side mounted

F

15

15

12.5

12.5

8

E

170
122

59

54

112

159.5

45

99

123.5

C

B

A

MS2-H150

OP-42174

MS2-H75/H100

OP-51627

MS2-H50

OP-51624

Matching model

Mounting bracket

D

20

30

40

MS2-H300

MS2-H50/H75/H100

B

D

10

C

3

A

15

F

(12)

E

J

H

27.5

I

Nominal diameter 3 Tapping depth 4 max.

Screw hole for mounting

10

14.3

122.5

2.5

16.1

(12)

120

85.5

16.5

60

28

28

15.5

4-M3 Screw insertion depth 5 max.

Screw hole for mounting

D

A

E

F

B

t=2

C

G

H

F

C

D

E

A

B

t=2

When bottom mounted

B

E

C

D

A

t=2

12.5

4-φ5

4-φ5

15

15

H

12.5

12.5

8

G

65

F

14.5

16

20.5

12.5

12.5

12.5

E

45

120.5

C

B

A

MS2-H150

MS2-H75/H100

OP-51629

MS2-H50

OP-51626

Matching model

Mounting bracket

75

60

157

75

54

153.5

D

40

50

50

132.5

160

55

54

150

122.5

45

135

107.5

C

B

A

MS2-H50

OP-42175

MS2-H75/H100

OP-51628

MS2-H150

OP-51625

Matching model

Mounting bracket

D

20

30

40

E

125

140

150

Model

A

99.5

114.5

B

40
52

C

14.7
15.1

D

14.6
17.1

E

97

110

F

65
78

G

33.4

41

H

40
52

I

5

4.75

J

30

42.5

MS2-H50

MS2-H75/H100

G

35.9

59

43.3

35.9

7

5

4-M3 Screw insertion depth 5 max.

Screw hole for mounting

78

21.5

120

10

35.9

46.5

96

16.5

131.5

70.5

140

2

16.8

124

(10)

P=10

Input current (100/200 VAC)

1.3 A/0.7 A max.

1.9 A/0.9 A max.

2.1 A/1.3A max.

2.2

3.9 A/1.8 A max.

18 A/36 A max.

A/1.1 A max.

Efficiency (100/200 VAC)
Leakage current
(100/200 VAC)

Starting time
Output holding time

2.7 A min.

4.0 A min.

5.3 A min.

7.9

15.6 A min

A min.

Display method
Memory backup time
Display resolution
Surrounding Air Temperature
(for operation)

Surrounding Air Temperature
(for storage)

Safety standard

Limits for harmonic current emissions

Approx. 27 0g

Approx. 470g

Approx. 490g

Approx. 700g

Natural air-cooling

Possible (OP-42207 is required.)

4

Possible (External diode is required.)

4

EN61000-3-2

3

FCC Part15B ClassA, EN55011 ClassA, EN61000-6-2

UL : UL508, UL60950-1

C-UL : CSA C22.2 No.14-M95, CSA C22.2 No.60950-1-03

EN : EN60950-1, EN50178

IEC : IEC60950-1

100 to 240 VAC ( 85 to 264 VAC, 110 to 370 VDC)

Model

3-digit, 7-segment LED (Character height: 10 mm)

Approx. 10 years (at 20

°C)

50/60 Hz ( 47 to 63 Hz, DC )

82%/85% typ. (with 100% load)

25 A/50 A max. (with 100% load, at 25

°C cold start)

24 VDC

180mVp-p max.

MS2-H50

MS2-H75

MS2-H100

MS2-H150

MS2-H300

Rated Input voltage

1

Rated Frequency

1

Rush current (100/200 VAC)

Rated output voltage
Adjustable voltage range
Rated output current

2.1 A(Class2)

3.2 A

4.5 A

12.5 A

6.5 A

Ripple/noise voltage
Input fluctuation
Load fluctuation
Temperature fluctuation

Overvoltage protection

2

Relative humidity

Shock

Vibration

Insulation resistance

EMC standard

Parallel operation
Serial operation
Cooling method

Weight

)

c

In X, Y, and Z directions, 2 hours respectively under the following conditions

10 to 57 Hz, 0.3 mm double-amplitude, 57 to 500 Hz, 19.6 m/s

2

(2G , 5.5-minute ycle

t

t

(

t

100 MΩ min. (with 500 VDC megohmmeter) (across input and output terminals)

(across input erminals and PE erminal) across output erminals and PE terminal)

0.4 mA/0.75 mA max. (with 100% load)

500 ms max. (at Surrounding Air Temperature of 0 to 55

°C under rated I/O conditions)

20 ms min. (at Surrounding Air Temperature of 25

°C under rated I/O conditions)

± 5%(with V.ADJ)

Peak acceleration: 300 m/s

2

, in X, Y, and Z directions,

2 times respectively

–10 to 55

°C, No condensation (See "Output Derating Characteristics".)

25 to 85%, No condensation

0.4 % max.
1.5 % max.

Activates when the voltage reaches 26.4 V or more. Voltage turn-off.

Operation resumes when the input power is turned on again.

t

t

t

t

500 VAC 50/60 Hz 1 min (across output erminals and PE erminal)

3.0 kVAC 50/60 Hz 1 min (across input and output terminals),

2.0 kVAC 50/60 Hz 1min (across input erminals and PE erminal)

0.02 %/

°C max.

Constant current voltage limiting. Automatic reset

–20 to 70

°C, No condensation

0.1 A/0.1 V/1%

Overcurrent protection

Withstand voltage

Input conditons

Output conditons

Protection

Displa

y

En

vironment

Applicab

le standard

Other

Approx. 1540g

∗1 For conforming to safety standards shown above, rated input voltage is 100 to 240 VAC 50/60 Hz.

∗2 To reset the unit, turn off the input power once, wait for 1 minute or more, and then turn on the input power again.

∗3 For MS2-H100, it is applied only when the load ratio is 70% or lower.

∗4 The Applicable standards do not apply for parallel and serial operations.

Output Derating Characteristics

MS2-H50/H150

MS2-H75

MS2-H100

MS2-H300

* The characteristic data shown above are obtained when this unit is installed as described in this

Manual.

* The surrounding air temperature is the temperature 50 mm below the bottom of the MS2 Series unit.

Dimensions

.8.

0.7

.

3

.

5

.

P

.8.

1.3

.

2

.

4.0

Load f

actor (%)

Load f

actor (%)

Load f

actor (%)

Load f

actor (%)

Surrounding air temperature (

°C)

Surrounding air temperature (

°C)

Surrounding air temperature (

°C)

Surrounding air temperature (

°C)

100

90
80
70
60
50
40
30
20
10

0

100

90
80
70
60
50
40
30
20
10

0

100

90
80
70
60
50
40
30
20
10

0

100

90
80
70
60
50
40
30
20
10

0

-10

0

10

20

30

40

50

70

60

-10

0

10

20

30

40

50

70

60

-10

0

10

20

30

40

50

70

60

-10

0

10

20

30

40

50

70

60

2

WARRANTIES AND DISCLAIMERS

: KEYENCE, at its sole option, will refund,

repair or replace at no charge any defective Products within 1 year from the date

of shipment. Unless stated otherwise herein, the Products should not be used

internally in humans, for human transportation, as safety devices or fail-safe

systems. EXCEPT FOR THE FOREGOING, ALL EXPRESS, IMPLIED AND

STATUTORY WARRANTIES, INCLUDING WARRANTIES OF

MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND

NONINFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY

DISCLAIMED. KEYENCE SHALL NOT BE LIABLE FOR ANY DIRECT,

INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF

DAMAGES RESULT FROM THE USE OF THE PRODUCTS IN ACCORDANCE

WITH ANY SUGGESTIONS OR INFORMATION PROVIDED BY KEYENCE.

In

some jurisdictions, some of the foregoing warranty disclaimers or damage

limitations may not apply.

E 1101-3

Copyright (c) 2004 KEYENCE CORPORATION. All rights reserved.
1274E 1033-3