beautypg.com

Main specifications – KEYENCE CV-5001 Series User Manual

Page 7

background image

7

*1 PNP open collector is used for main unit of model types with P in the end.
*2 Models that install the Ethernet port to the CPU unit support Ethernet port direct connection.

Main Specifications

CV-5701

CV-5501

CV-5001

Pixels

When CV-H500C/H500M is connected (CV-5701 only)
• 5 megapixel mode: 2432(H) x 2050(V), approx. 4,990,000 pixels
When CV-200C/S200C/H200C/200M/S200M/H200M is connected
• 2 megapixel mode: 1600 (H) x 1200 (V), approx 1,920,000 pixels
• 1 megapixel mode: 1024 (H) x 960 (V), approx 980,000 pixels
When CV-H100C/H100M is connected
• 1 megapixel mode: 1000 (H) x 1000 (V), approx 1,000,000 pixels
When CV-035C/S035C/H035C/035M/S035M/H035M is connected
• 240,000 pixel mode: 512(H) x 480(V), approx. 240,000 pixels
• 310,000 pixel mode: 640(H) x 480(V), approx. 310,000 pixels

• 512 (H) x 480 (V), approx 240,000 pixels
• 640(H) x 480(V), approx. 310,000 pixels

Camera input

• Two color/monochrome cameras

(Compatible with (CV-H500C/H200C/
200C/S200C/H100C/035C/S035C/H035C/
H500M/H200M/200M/S200M/H100M/
035M/S035M/H035M, mixed connection
possible)

• Two extra cameras can be connected by

using expansion unit CVE500. Up to four
cameras can be connected.

• Two color/monochrome cameras

(Compatible with CV-H200C/200C/S200C/
H100C/035C/S035C/H035C/200M/
S200M/H100M/035M/S035M/H035M,
mixed connection possible)

• Two extra cameras can be connected by

using expansion unit CVE500. Up to four
cameras can be connected.

Two color/monochrome cameras (CV-035C/
S035C/H035C/035M/S035M/H035M can be
connected. Mixed connection is possible.)

Main image processor

DSP (High-speed)

DSP

Number of programs registered

SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD card and the size of the programs), external switching
possible

Number of registered screens

Maximum 1000 screens for each program (depending on SD card size), Compressed saves possible

SD card

SD card slot x2 (SDHC compatible)
Compatible with OP-87133 (512 MB: standard in SD1 slot for CV-5501/5001), CA-SD1G (1GB: standard in SD1 slot for CV-5701),
CA-SD4G (4GB: SDHC)

Interface

Control
input

External trigger input

2 points
EV compatible input rating: 26.4 V or less, 3 mA or more
4-camera simultaneous capture/individual capture can be selected (when CV-E500 is not
connected, images from up to two cameras can be captured at the same time).

2 points
EV compatible input rating: 26.4 V or less,
3 mA or more
2-camera simultaneous capture/individual
capture can be selected.

Individual trigger delay (0 to 999 ms) can be selected for each trigger input

Control input

18 inputs
Input rating 26.4 V or less, 2 mA or more

Control
output

General purpose
output

27 outputs NPN/PNP (including two FLASH outputs linked to external trigger.)

Total status output

1 output, NPN/PNP open collector, maximum 50 mA (30 V or less)
Supports total status hold control and one shot output (1 to 9999 ms)

Monitor output

SVGA 800x600 (24-bit color 60 Hz)

Operation indicators

Power, Error LED display

RS-232C

Numerical value output, image data (compressible) and control input/output enabled. Can be used simultaneously with other communication
ports.
Maximum baud rate of 115200 bps is supported.
Do not use to connect to PLC link, CC-Link, or EtherNet/IP

PLC link

Numerical value output and control input/output using the RS-232C port or Ethernet port enabled.
Following PLCs are supported via link unit*

2

:

• Keyence Corp.: KV-700 series, KV-1000 series, KV-3000 series, KV-5000 series, KV-5500 series
• Mitsubishi Electric: A series (RS-232C only), Q series, L series
• OMRON: SYSMAC C series (RS-232C only), CP1/CS1/CJ1/CJ2 series
• Yaskawa Electric: MP900 series (RS-232C only)/MP2000 series
Do not use to connect to CC-Link, RS-232C, or EtherNet/IP

CC-Link

By connecting the optional CC-Link unit CA-NCL10E, numerical value input/output and control input/output are enabled.
• Supports remote device station, Ver. 2.00/1.10
• Do not use to connect to PLC link, RS-232C, or EtherNet/IP

EtherNet/IP

Numerical value input/output and control input/output enabled while using an Ethernet port
• Supports periodic communication (Max. 1436 bytes), supports message communication
• Up to 128 units can be connected
• Compliant with compliance test Version.A5
• Do not use to connect to PLC link, RS-232C, or CC-Link

Ethernet

Numerical value output, image data (compressible) and control input/output enabled.
Can be used simultaneously with other communication ports.
100BASE-TX/10BASE-T

USB

Numerical value output, image data (compressible) and control input/output enabled.
Can be used simultaneously with other communication ports
USB2.0 HI-SPEED compatible

Illumination control

By connecting the optional illumination expansion unit, LED illumination (12 V, 24 V) and intensity control are enabled.
• 2 channels per unit, connect up to 4 units
• Supports multi-pattern illumination function

Display language

Japanese/English/German/Italian/French/Traditional Chinese/Simplified Chinese selectable

Rating

Power supply voltage

24 V DC ±10%

Current consumption

2.4 A (2 cameras at maximum load) /3.2 A (4 cameras at maximum load)

2.2 A (2 cameras at maximum load)

Environmental
resistance

Ambient operating temperature

• With two cameras connected: 0 to +50°C (0 to +45°C with min. 1 megapixel camera

connected)

• With four cameras connected: 0 to +45°C

0 to +50°C

Ambient operating humidity

35 to 85% RH (no condensation)

Weight

Approx. 1250 g