6APPENDICES

6-1

Troubleshooting

This appendix describes troubles that may occur during the use of this product and troubleshooting
methods. Check the following table before sending in your SJ-F031/036 Series for repair.

Symptom

Check Item

Remedy

Monitor LEDs or

indicators are not

lit.

Power will not be

turned on.

Power is turned on but

the fan will not rotate.

Static is not

eliminated.

Static elimination is not

performed properly.

The blow rate is

reduced.

The ion level

alarm is output or

displayed.

The condition

alarm is output or

indicated.

The alarm

indicator lights up.

Control output is

not output correctly.

Static elimination stop

input is not input correctly.

Is the power supply connected

properly?

Is a power supply within specification

being used?

Is there sufficient power capacity?

Is static elimination turned off?

Are the electrode needles worn or dirty?

Is static elimination stop currently set?

Is the abnormal discharge detection

function operating?

Are conductors or other Static Elimination Blowers

located near the Static Elimination Blower?

Is the blow rate adjustment setting

set to low?

Is the filter on the back panel of the

blower clogged?

Are the electrode needles worn or dirty?

Are conductive objects located in the area

within 50 mm in front of the electrode needles?

Are conductors or other Static Elimination Blowers

located near the Static Elimination Blower?

Are the electrode needles worn or dirty?

-

Is wiring correct?

Is wiring correct?

Connect the AC adaptor and the I/O

cable correctly.

Use a power supply that is within

specification.

To use a 24 VDC power supply, use a

DC power supply with enough capacity.

Turn on static elimination by following

the instructions of "Starting and

Stopping Static Elimination" (page 5).

Perform maintenance on the electrode

needles or replace the electrode unit.

"Performing Maintenance on the

Electrode Needles" (page 7).

Cancel the static elimination stop input

of the SJ-F031/036.

Check the electrode unit for any

conductive substances (e.g. oil droplets).

Keep the Static Elimination Blower away from

conductors or other Static Elimination Blowers.

Refer to "Adjusting Blow Rate of the

Static Elimination Blower" (page 5).

Clean the clogging duct and refuse off

the filter.

"Performing Maintenance on the Air

Filter" (page 7).

Perform maintenance on the electrode

needles or replace the electrode unit.

Keep the conductive objects away from the area

within 50 mm in front of the electrode needles.

Keep the Static Elimination Blower away from

conductors or other Static Elimination Blowers.

Perform maintenance on the electrode

needles or replace the electrode unit

Refer to "During an alarm

(levels 1, 2)" (page 9).

Check the output circuit and wiring,

and connect correctly.

Check the input circuit and wiring, and

connect correctly.

6-2

Table of Indicated States

This appendix describes the various indicated states of the SJ-F031/036.

Indicated states when the power is turned ON

Indicated states during setting change, confirmation and operation

(excluding when the power is turned ON)

Lit State

Description

After the center LED of the monitor lit in red, the
state that was active before the power was turned
OFF is displayed. (charge monitor, ion level
monitor or blow rate setup monitor)

After the center LED of the monitor lights in red,
static elimination is performed with the display of
the state that was active before the power was
turned off, such as the charge monitor, ion level
monitor or blow rate setup monitor.

Two monitor LEDs on the + side and - side,
respectively, and the ion level indicator light in red.

One monitor LED and the blow rate indicator light in red.

Ion level monitor display

This displays the amount of ions that are being

emitted by the SJ-F031/036.

This displays the setting value of the blow rate of

the Static Elimination Blower.

The center LED of the monitor lights in red.

Static elimination stop input (I/O terminal section)
The center LED of the monitor lights in red when
static elimination is turned off by shorting the static
elimination stop input wire and the 0 V wire.

Static elimination stop input (Operation panel)
The center LED of the monitor lights in red when
static elimination is stopped by pressing for
about two seconds.

One monitor LED and the ion balance indicator

light in red.

Charge monitor display
This displays the charged level of the target
object. When there is a plus charged object, the
LED on the + side lights, and when there is a
minus charged object, the LED on the - side lights
to indicate the charged level.

Lit State

Description

6-2

Table of Indicated States

Lit State

Description

Ion balance manual setup

In ion balance manual setup, press and hold or

000

to set the zero point.

The position of the LED that is lit up moves with

the cursor to light up the center LED.

Refer to "Adjusting Ion Balance" (page 5) for

details about how to start ion balance manual

setup.

One of the monitor LEDs lights.

Ion level alarm indicator blinks in red.

Ion level alarm

The ion level alarm indicator blinks in red when the

ion level decreases lower than the setting value.

Ion balance indicator blinks in red.

Ion balance manual setup start

Pressing and holding for about two seconds

while the ion balance indicator lights up starts ion

balance manual setup, when the ion balance

indicator starts blinking in red.

Condition alarm indicator blinks in red.

Condition alarm

The condition alarm indicator blinks in red when

the ion balance is unstable due to influence of the

installation environment.

The state (charge monitor, ion level monitor or

blow rate setup monitor) that was active before

static elimination was turned OFF is displayed.

Static elimination stop input canceling
(Operation/Display section)
Pressing and holding for about two seconds
after static elimination is turned off using
cancels the static elimination stop input. The state
(charge monitor, ion level monitor or blow rate
setup monitor) that was active before the static
elimination was stopped is restored.
Note that when an alarm condition occurs, the
LED blinks to indicate the cause of the alarm.
Refer to "During an alarm (levels 1, 2)"
(page 9) for indicated states during an alarm.

6-2

Table of Indicated States

Description

The three center LEDs of the monitor blink in red.

During an alarm (level 1)

The three center LEDs of the monitor blink in red

under the following conditions.

Remove the cause of alarm condition, and then

press and hold and for about three

seconds simultaneously.

The alarm condition will be cancelled. You can

turn on the power.

Cause of alarm condition

· The lock switch is disengaged.

· The rear cover or the front cover is not properly

attached.

During an alarm (level 2)

All the monitor LEDs blink in red under the

following conditions.

Remove the cause of alarm condition and then

turn on the power.

If the alarm is output repeatedly, please contact

your nearest KEYENCE sales office.

Cause of alarm condition

· Discharged abnormally

· Electrode unit not attached

· Internal memory value trouble

· Internal circuit damaged

How to initialize the internal memory

· Turn on the power by holding down and .

Lit State

All the monitor LEDs blink in red.