Operation
Starting and Stopping Static Elimination
Turning on the power of the fan of the Static Elimination Blower and applying voltage to the electrode
needles generates ions to start static elimination. This section describes how to start static elimination.
In the default setting, turning on the power starts static elimination automatically.
If static elimination is stopped before turning the power off, the next time the power is turned on,
static elimination will not start automatically.
■ Starting and Stopping static elimination
Press and hold
for about two
seconds, then static elimination
starts.
Press and hold
for about two
seconds again, and then static
elimination will stop.
Tip
3-1
Operation
Adjusting Blow Rate of the Static Elimination Blower
This blow rate adjustment enables static elimination from a wider area.
1
Press
or to select the blow
rate indicator.
The blow rate indicator lights in red.
2
Press and hold
for about two
seconds to select the adjustment
mode.
The blow rate indicator blinks in red.
3
Press
or
to adjust blow
rate.
The monitor LED lights to indicate
the blow rate selected.
Pressing and holding
or
enables continuous adjustment of blow rate.
4
Press
to complete the blow
rate setup.
Increases blow rate.
Decreases blow rate.
Blow rate indicator
Tip
3-1
Operation
Adjusting Ion Balance
The SJ-F031/036 senses the charged amount of the target object by the I.C.C. function to automatically
control the emission (balance) of plus and minus ions.
The zero point, the point for reference for the I.C.C. function, is adjusted before shipment. However, in
some environments, the zero point sometimes drifts. If this reference zero point drifts, adequate static
elimination cannot be maintained.
The SJ-F031/036 allows arbitrary adjustment of ion balance.
■ Ion balance adjustment
1
Press
or
to select the ion
balance indicator.
The ion balance indicator lights in red.
2
Press and hold
for about two
seconds.
The ion balance indicator blinks in
red and the ion balance adjustment
mode is selected.
3
Press
or
to adjust ion balance.
4
Press
to complete the ion
balance setup.
The zero point moves to the
+ side.
The zero point moves to the
- side.
Ion balance indicator
3-1
Operation
■ Confirmation and clear of the ion balance setting value
1
Press and hold
for about two
seconds with the ion balance
displayed.
The ion balance indicator blinks in
red and the ion balance adjustment
mode is selected.
2
Press
and
or
simultaneously.
The monitor displays the ion
balance setting. You can
confirm the adjusted state from
the color and the position of the
LED that lights up. Pressing
and holding
and
or
simultaneously for about three
seconds clears the adjustment
values.
3
Press
to complete the adjustment.
Turning Off Static Elimination
Use any of the following methods to stop static elimination while leaving the unit powered on.
■ Operation using the I/O Cable
Shorting the pink wire (static elimination stop input wire) and the orange wire (power ground wire) of the
I/O cable turns off static elimination.
■ Operation using the Operation Panel
Pressing and holding
for about two seconds turns off static elimination.
When static elimination turned off, the center LED of the monitor lights in red.
If static elimination is turned off from the operation panel before turning off the power, turning
on the power next time will not start static elimination automatically.
Refer to
"Starting and Stopping Static Elimination" for details about how to start static
elimination.
Ion balance indicator
Without adjustment
Lit in green
Adjustment in the
+ direction
Lit in orange
Full adjustment in
the + direction
Lit in red
Tip