5

3-1

Operation

Starting and Stopping Static Elimination

Turning on the power of the fan of the Static Elimination Blower and applying voltage to the electrode
needles generates ions to start static elimination. This section describes how to start static elimination.

In the default setting, turning on the power starts static elimination automatically.
If static elimination is stopped before turning the power off, the next time the power is turned on,
static elimination will not start automatically.

Starting and Stopping static elimination

Press and hold

for about two

seconds, then static elimination
starts.
Press and hold

for about two

seconds again, and then static
elimination will stop.

Tip

3-1

Operation

Adjusting Blow Rate of the Static Elimination Blower

This blow rate adjustment enables static elimination from a wider area.

1

Press

or to select the blow

rate indicator.
The blow rate indicator lights in red.

2

Press and hold

for about two

seconds to select the adjustment
mode.
The blow rate indicator blinks in red.

3

Press

or

to adjust blow

rate.
The monitor LED lights to indicate
the blow rate selected.

Pressing and holding

or

enables continuous adjustment of blow rate.

4

Press

to complete the blow

rate setup.

Increases blow rate.

Decreases blow rate.

Blow rate indicator

Tip

3-1

Operation

Adjusting Ion Balance

The SJ-F031/036 senses the charged amount of the target object by the I.C.C. function to automatically
control the emission (balance) of plus and minus ions.
The zero point, the point for reference for the I.C.C. function, is adjusted before shipment. However, in
some environments, the zero point sometimes drifts. If this reference zero point drifts, adequate static
elimination cannot be maintained.
The SJ-F031/036 allows arbitrary adjustment of ion balance.

Ion balance adjustment

1

Press

or

to select the ion

balance indicator.
The ion balance indicator lights in red.

2

Press and hold

for about two

seconds.
The ion balance indicator blinks in
red and the ion balance adjustment
mode is selected.

3

Press

or

to adjust ion balance.

4

Press

to complete the ion

balance setup.

The zero point moves to the
+ side.

The zero point moves to the
- side.

Ion balance indicator

3-1

Operation

Confirmation and clear of the ion balance setting value

1

Press and hold

for about two

seconds with the ion balance
displayed.
The ion balance indicator blinks in
red and the ion balance adjustment
mode is selected.

2

Press

and

or

simultaneously.
The monitor displays the ion
balance setting. You can
confirm the adjusted state from
the color and the position of the
LED that lights up. Pressing
and holding

and

or

simultaneously for about three
seconds clears the adjustment
values.

3

Press

to complete the adjustment.

Turning Off Static Elimination

Use any of the following methods to stop static elimination while leaving the unit powered on.

Operation using the I/O Cable

Shorting the pink wire (static elimination stop input wire) and the orange wire (power ground wire) of the
I/O cable turns off static elimination.

Operation using the Operation Panel

Pressing and holding

for about two seconds turns off static elimination.

When static elimination turned off, the center LED of the monitor lights in red.

If static elimination is turned off from the operation panel before turning off the power, turning
on the power next time will not start static elimination automatically.
Refer to

"Starting and Stopping Static Elimination" for details about how to start static

elimination.

Ion balance indicator

Without adjustment

Lit in green

Adjustment in the
+ direction

Lit in orange

Full adjustment in
the + direction

Lit in red

Tip