Names and Functions of Parts

Front view

Electrode Unit

Provided with the electrode needles. Remove the Electrode Unit before attempting maintenance and
servicing work.

Refer to

"Performing Maintenance on the Electrode Needles" (page 7) for details about how to

remove the Electrode Unit.

Electrode needle

Generates ions from its tip.

Lock switch

Affixes the Electrode Unit.

Fan guard

SJ-F031: Metal
SJ-F036: Resin

Operation panel

START

/STOP

BALANCE

ION

FAN

COND

IONLEVEL

Lock switch

Operation panel

Fan guard

Electrode Unit

Electrode needle

[1] Ion level alarm indicator

Lit OFF

Normal

Blinking in red

Ion level alarm has occurred.

[2] Condition alarm indicator

Lit OFF

Normal

Blinking in red

Condition alarm has occurred.

[3] Ion balance indicator

When lit, the indicator displays the ion balance.

[4] Ion level indicator

When lit, the indicator displays the ion level.

[5] Blow rate indicator

When lit, the indicator displays the blow rate setting value.

[6] Monitor

The monitor displays the ion balance, ion level, blow rate setting value in
seven indication levels.

Lights in red when the Static Elimination Blower needs cleaning.

[7] START/STOP key

Used for switching start/stop.

[8] ENTER key

Used for selecting various setups.

[9] UP/DOWN key

Used for selecting and adjusting various setups.

[1]

[6]

[9]

[2]

[3] [4] [5]

[7]

[8]

1-3

Names and Functions of Parts

Rear view

I/O cable

Input circuit diagram

*Static elimination stop input

Output circuit diagram

Open collector output

*Alarm output, Condition/Ion level alarm output

DCI

N

Power supply connector

I/O cable connector

Ground terminal

* The blue and orange wires are connected internally.

Wire color

Description

Brown

DC power supply (Rating: 24 V)

Blue

Power GND

Pink

Static elimination stop input signal
(Static elimination can be turned on or off by
shorting this wire and the orange wire.)

Orange

Output signal GND

Black

Ion level alarm output signal

White

Condition alarm output signal

Gray

Alarm output signal

Shielded wire
(Thick black wire)

Ground lead (Connect to a Class D ground.)

+24V

3k

Ω

INPUT*

0V

470

Ω

Input zero-voltage contact (relay, etc.) or NPN open
collector to INPUT.

OUTPUT*
DC40V
100mA

0V

0V

2CONNECTION AND INSTALLATION

2-1

Before Installation

Before you install this product, examine carefully the distance between the Static Elimination Blower
and the target object and the time required for static elimination.

About Static Elimination Performance

The following shows a typical example where static is eliminated from an aluminum plate (20 pF)
150 mm x 150 mm square charged to +1000 V by this product.
The blow rate of the blower is set at maximum (FAST).

Static elimination area

The following graphs show the relationship between the time required for eliminating static from a target
object charged from +1000 V to +100 V and the distance from the charged object up to the Static
Elimination Blower.

Static elimination time

The following graphs show the relationship between the time required for eliminating static at the
maximum blow rate from a target object charged at +1000 V positioned 300 mm apart from the Static
Elimination Blower and the charged level.

200

400

800

1000

1200

1400

1600mm

600

600mm

600mm

0

1s

2s

3s 4s

5s

SJ-F031

200

400

800

1000

1200

1400

1600mm

600

600mm

600mm

0

1s

3s

4s

5s

SJ-F036

2s

0

1

2

3

4

1

0.8

0.6

0.4

0.2

0

-0.2

Time required for static elimination (sec)

Charged level (kV)

SJ-F031

0

1

2

3

4

1

0.8

0.6

0.4

0.2

0

-0.2

Time required for static elimination (sec)

Charged level (kV)

SJ-F036

2-1

Before Installation

Appropriate static elimination method

Pay attention to the following points to ensure that static
elimination is performed appropriately.

Static elimination cannot be performed accurately at
locations where the target object is touching a metallic
body (grounded body).
Eliminate static from the target body at locations where it is
not directly touching metallic bodies (grounded body).

Static will be eliminated from only the surface of the
insulated body (film, sheet, etc.) that is facing the Static
Elimination Blower.
When eliminating static from both sides of a target body,
install two Static Elimination Blowers as one unit must be
installed on either side of the target body.

Install the Static Elimination Blower so that it can be easily accessed, for example, for
replacement of parts and cleaning.

Installation Precautions

Installation site

Refer to the following diagram when installing the SJ-F031/036.
• Install the Static Elimination Blower away from the wall or surrounding objects.

• Install the Static Elimination Blower so that the Electrode Unit can be removed for replacement.

Interference

The Static Elimination Blower may not function properly if two or more units are used close to each other.
In such an installation, refer to the following diagram and maintain the indicated distance between units.

START

/STOP

BALANCE

ION

FAN

COND

IONLEVEL

OK

NG

OK

Film, sheet or other electrically charged object

Metal roller

Note

50 mm or more

50 mm or more

15 mm

or more

START

/STOP

START

/STOP

1

1

1

1