Attach ethernet to this connector, Compatible cables, Connecting the cable – KEYENCE DL-EP1 User Manual
Page 3: Specifications, Dimensions
3
z
Connecting to a large display type sensor amplifier
1
Connect the sensor amplifier to the EtherNet/IP Compatible Network Unit DL-EP1
using the optional expansion cable (OP-35361).
2
Detach the sensor amplifier connector (for DIN rail mounting type) of the
EtherNet/IP Compatible Network Unit DL-EP1 with pliers and mount the attached
expansion connector sticker.
Methods for connecting the DL-EP1 to the Ethernet are explained in this section.
Compatible cables
An STP (shielded twisted-pair) cable or UTP (unshielded twisted-pair) cable is used to con-
nect the DL-EP1 to the Ethernet.
The compatible cables differ when Ethernet is structured of 10BASE-T or 100BASE-TX.
Connecting the cable
Connect the network cable to the RJ-45 connector.
*1 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.
*2 Varies with the sensor amplifiers connected.
• Turn OFF the power before connecting the expansion cable
and connect securely. Diagonal or otherwise improper inser-
tion may damage the equipment.
• Inserting or pulling the cable when the power is turned ON
may damage the equipment.
Attach Ethernet to This Connector
Ethernet
Compatible cables
10BASE-T
STP cable or Category 3 or higher UTP cable
100BASE-TX
STP cable or Category 5 or higher UTP cable
• Use a straight cable when connecting DL-EP1 to the Ethernet switch.
• Use a cross cable when connect the DL-EP1 directly to a personal
computer.
Detach the
protection sticker
Detach the
protection
sticker
Expansion cable (cable length:300mm)
NOTICE
Sensor amplifier connector
(for DIN rail mounting type)
Expansion
connector
sticker
Reference
Specifications
Product name
EtherNet/IP Compatible Network Unit
Model
DL-EP1
Ethernet
Specifications
Compliant
standards
IEEE802.3 (10BASE-T)
IEEE802.3u (100BASE-TX)
Transmission rate
10Mbps (10BASE-T)
100Mbps (100BASE-TX)
Transmission
medium
STP cable or Category 3 or higher UTP cable
(10BASE-T)
STP cable or Category 5 or higher UTP cable
(100BASE-TX)
Maximum cable
length
100 m (Distance between DL-EP1 and Ethernet switch)
Maximum number
of connectable
hubs
4 (10 BASE-T)
2 (100 BASE-TX)
EtherNet/IP
Specifications
Compatible
functions
Cyclic communication
Compatible with UCMM and Class 3 messaging
(Explicit messaging)
Number of
connections
64
RPI
(Transmission
cycle )
0.5 to 10000 ms (0.5 ms unit)
Tolerable
communication
bandwidth for
cyclic
communication
6000 pps
Conformance test Compatible with Version A7
Sensor
connection
specifications
Connectable
sensors
Sensor amplifiers with D-bus support
*1
Number of
connectable
sensor units
15 units max
*2
Indicator lamps
Link/activity indicator (LINK/ACT)?Green LED
Module status indicator (MS)?2-color (green/red) LED
Network status indicator (NS)?2-color (green/red) LED
Sensor communication indicator (N-bus): 2-color
(green/red) LED
Power voltage
20 to 30 VDC ±10%, including ripple (p-p)10%
(supplied from the connected sensor amplifiers)
Power consumption
1500 mW or less (at 30 V 50 mA max)
Environmental
resistance
Operating
surrounding air
temperature
-20 to 55 °C (no freezing)
Operating
surrounding air
humidity
35 to 85% RH (no condensation)
Vibration
resistance
10 to 55 Hz compound amplitude 1.5 mm, 2 hours each
in X, Y, Z directions
Pollution degree
2
Materials
Main unit case: Polycarbonate
Weight
Approx. 70 g
Dimensions
25.6
35.4
43.5
94.5
38.1
(42.5
)
29.4
(mm)