beautypg.com

Control an expansion unit [fs-t2(p), Connecting fiber unit, Mounting main unit – KEYENCE FS-V1(P) User Manual

Page 3: Mutual interference suppression function, Mounting expansion units, 3control an expansion unit [fs-t2(p)

background image

3

CONTROL AN EXPANSION UNIT [FS-T2(P)]

1. To change the channel, press

[UP] (or [DOWN]) while holding

[MODE].

Select the channel for the

expansion unit [FS-T2(P)] to be

controlled.

2. You can monitor the expansion

unit [FS-T2(P)] or change its

sensitivity setting value using

the same procedures as for the

FS-V1(P).

• You cannot use the FS-V1(P)’s SET button to set the sensitivity of the

expansion unit.

• The red LED and green LED turn ON and OFF in response to the

expansion unit [FS-T2(P)] turning ON and OFF.

Note 1: You cannot control the [FS-M2(P)] (Manual calibration model).

Note 2: The channel for the [FS-M2(P)] is displayed as “------”. The

red LED and green LED turn ON and OFF in response to the [FS-

M2(P)] turning ON and OFF.

Note 3: If you add an FS-V20 Series expansion unit, you may not be

able to control the FS-V20 Series and any expansion units added after

the FS-V20 Series .

CONNECTING FIBER UNIT

Lower the quick-release lever, insert the fiber unit about 14 mm until it

reaches the end, and then lift the quick-release lever.

• To connect a fiber unit with a small diameter, use the adaptor

included with the FU series.

1. Attach the adaptor to the fiber

unit.

2. Fully insert the adaptor into the

mounting holes of the amplifier,

and then lift the quick-release

lever.

Note: If the fiber unit is improperly connected, the sensor cannot meet
the specifications.
• The required adaptor is included in each model of the FU series. If an

inadequate adaptor is used, the fiber unit cannot be properly installed.

• To connect the coaxial reflective type fiber unit to the amplifier, con-

nect the single-core fiber to the transmitter side, and connect the

multiple-core fiber to the receiver side.

(Connect the fibers according to the marking on the amplifier lateral side.)

MOUNTING MAIN UNIT

„

Mounting/Detaching the unit to/from a DIN rail or the

mounting bracket.

Hook the claw located at the unit cable side onto the DIN rail, and then hook the
front side claw to the rail while pressing the amplifier forward. To detach the
unit, unhook the front claw by lifting the unit front side while pressing it forward.

„

Mounting a unit laterally

Secure the screws through the mounting bracket’s side hole (accessory)

MUTUAL INTERFERENCE SUPPRESSION FUNCTION

When using several fiber units, each fiber unit is free from light

interference from up to 4 adjacent fiber units.

When the fiber units are mounted closely, each fiber unit and its 4 adja-

cent units are designed to receive light at different pulse frequencies to

avoid interference.

You can mount the FS-T(P) series and

the FS-M(P) series together within the

same system.
Note: If you do not use the expansion-

units, the mutual interference suppress

function is not available.

MOUNTING EXPANSION UNITS

„

Mounting EXPANSION units

1. Detach the protective cover from the

unit’s side panel.

2. Mount units to a DIN rail one by one.

3. Slide one expansion unit toward

another. Align the front claws of the

units and push the unit together until

they click.

4. Fix the units together by pushing an

end unit onto each end. (The end units

are included in the expansion unit)

„

Detaching units from DIN rail

1. Remove the end units.

2. Slide the expansion units apart, and

detach them individually.

(Do not detach multiple units connected together with end units.)

The sticker shown on the right is
included in the expansion unit. Apply
this sticker near the sensor.

AB

MODE

SET

#

2

CH

CH2

CH17

CH4

CH3

Expansion units

Channel
display

1

2

1

2

Cable outer dia.

Type

Shape

φ1.3

Adaptor A

(OP-26500)

φ1.0

Adaptor B

(OP-26501)

Multiple-core

Single-core

Transmitter

Receiver

Mounting

Detaching

M3 screw

• When several units are connected, confirm the ambient temper-

ature. (See "Specifications" on P. 1.)

• To connect several units, be sure to use a DIN rail and end units.

• To mount or detach several units, be sure to turn the power off.

• Do not remove the protective cover of the expansion connector

on the outmost unit.

NOTICE

Main unit

Up to 16 expansion units
can be connected.

Remove the protective cover.

End unit
(Included
with FS-T2)

Expansion
unit

1. The FS-T1(P)/M1(P) can be used as the

same unit as well as the FS-V1(P).

2. FS-M2(P) can be used as the expansion unit

as well as the FS-T2(P).

1.

2.

Align the claw.

Slide the unit to the
right to remove it.