Other functions (common to c, c + i, and i modes), Locking the sensitivity setting, Selecting ch display – KEYENCE CZ-V1 User Manual
Page 6: Controlling expansion units (fs-t2, fs-v12, ps-t2), External synchronization function
6
OTHER FUNCTIONS (COMMON TO C, C + I, AND I MODES)
Locking the sensitivity setting
Hold down the MODE button and press the UP button for 3 seconds.
This locks the operation buttons.
• “Loc” flashes on and off on the LCD display monitor.
• You can still change the display mode and channel when in setting
locked status.
● To cancel the locked status
Repeat the procedure above while in
setting locked status. “UnL” flashes on and
off on the LCD display monitor.
Setting sensitivity using an external input
(External calibration function)
1. Lock the sensitivity setting using the
procedure above. (If “UnL” is displayed,
repeat the same procedure.)
2. Connect the pink cable to a switch or a PLC.
The minimum input time is 20 ms.
3. The external calibration procedure is the same as using the SET
button. (
➞ All the setting procedures on pages 4 and 5 are available
with the external input.)
Selecting CH display
The CZ-V1 can internally store 8 colors (banks). The banks can be
selected using the buttons or an external input.
● Selecting registered colors (banks) using the buttons
1. Hold down the MODE button*
and press the DOWN button for 3
seconds.
“CH” appears and flashes on the
LCD display.
2. Hold down the MODE button*
and momentarily press the UP/
DOWN button. The banks are
changed each time the UP/
DOWN button is pressed.
There are 8 banks from A
through H.
3. To finish the selection, hold down the MODE button and press the
DOWN button for 3 seconds.
“CH” stops flashing and remains illuminated.
* Be sure to hold down the MODE button first when operating the
MODE and UP/DOWN buttons.
CH
1234
MODE
SET
N.O
N.C
OFF
DRY.
OUT TIM SET
2
1
➞
NPN
+V
0 V
Brown
Blue
Pink
CH
1234
MODE
SET
N.O
N.C
OFF
DRY.
OUT TIM SET
2
1
CH
1234
MODE
SET
N.O
N.C
OFF
DRY.
OUT TIM SET
2
1
MODE
+
+
MODE
CH
1234
MODE
SET
N.O
N.C
OFF
DRY.
OUT TIM SET
2
1
CH
➞
● Selecting registered colors (banks) using an external input
The external bank selection cable allows the selection of 8 registered
colors from A through H.
+V
0V
Brown
Blue
Orange/purple
Yellow/purple
Green/purple
Controlling expansion units (FS-T2, FS-V12, PS-T2)
1. When “CH” is displayed, hold down the MODE button and momentar-
ily press the UP/DOWN button. You can change the channel of the
amplifier being controlled. Select the channel of the desired expan-
sion unit.
• The number of channels varies depending on the connected
expansion units. Up to 16 expansion units can be connected.
• The channel number starts at 2, which is the number of the expan-
sion unit next to the main unit, and it increases to 3 through to 17.
CH
CH2 CH3 CH4
CH17
CH
r
o
l
o
c
e
l
b
a
C
k
n
a
B
/
e
g
n
a
r
O
e
l
p
r
u
p
/
w
o
l
l
e
Y
e
l
p
r
u
p
/
n
e
e
r
G
e
l
p
r
u
p
A
X
X
X
B
●
X
X
C
X
●
X
D
●
●
X
E
X
X
●
F
●
X
●
G
X
●
●
H
●
●
●
●:
X:
MODE
+
+
MODE
2. You can use the CZ-V1 to operate the selected expansion unit, for
example to change the monitor display or sensitivity setting.
* The red and green color of the LCD display represents the ON/OFF
condition of the selected expansion unit.
Note 1: The FS-M2 cannot be controlled using the CZ-V1.
Note 2: When the channel of the FS-M2 is selected, “- - - -” appears on
the LCD display. (The red or green color of the LCD display represents
the ON/OFF condition of the FS-M2.)
External synchronization function
When the external synchronization input cable (purple) receives a
signal (connected to 0 V), the control output retains the condition at that
exact moment.
Channel
Main unit
Expansion unit
Channel number
indication
1-line expansion units
ON
OFF
ON
OFF
Detection
condition
Match
Mismatch
External
synchronization
input
Control output
This output
condition is
retained.
This output condition
is retained.