Port 1 set to Auto and Aout set to no.
1. After weight is applied, and if the weight is greater than the accumulate threshold, the indicator will
flash all the green ACCEPT LEDs for one second showing that the weight has been stored as an
accumulation.
2. If a print is to occur, press print and port 1 will transmit the following:
“Weight nn = wwwwww uu GR/NT”
nn is the number of the current accumulated weight in numerical order.
wwwwww is the last accumulated weight.
uu is the unit of weight accumulated.
GR or NT represent whether accumulated weight is gross or net respectively.
3. Weight on the scale must now be removed to less than .5 grads before the next accumulation can
occur.
4. Repeat steps 1-3 to continue accumulations (up to 99).
Port 1 set to button and Aout set to yes.
1. After weight is applied, and if the weight is greater than the accumulate threshold press
program/enter. The indicator will check to ensure there is no motion. If scale is in motion, the
indicator will wait up to 10 seconds for motion to stop. If the weight is not stable after 10 seconds,
the scale will disregard the request for accumulation. If stability occurs, the green ACCEPT LEDs
will flash for 1 second showing that the weight has been stored as an accumulation.
2. If a print is to occur, press print and port 1 will transmit the following:
“Weight nn = wwwwww uu GR/NT”
nn is the number of the current accumulated weight in numerical order.
wwwwww is the last accumulated weight.
uu is the unit of weight accumulated.
GR or NT represent whether accumulated weight is gross or net respectively.
3. Weight on the scale must now be removed to less than .5 grads before the next accumulation can
occur.
4. Repeat steps 1-3 to continue accumulations (up to 99).
Port 1 set to button and Aout set to no.
After weight is applied, and if the weight is greater than the accumulate threshold press program/enter. The
indicator will check to ensure there is no motion. If scale is in motion, the indicator will wait up to 10 seconds
for motion to stop. If the weight is not stable after 10 seconds, the scale will disregard the request for
accumulation. If stability occurs, the green ACCEPT LEDs will flash for 1 second showing that the weight has
been stored as an accumulation.
1. If a print is to occur, press print and port 1 will transmit the following:
“Weight nn = wwwwww uu GR/NT”
nn is the number of the current accumulated weight in numerical order.
wwwwww is the last accumulated weight.
uu is the unit of weight accumulated.
GR or NT represent whether accumulated weight is gross or net respectively.