beautypg.com

Input shaft, Disassembly, Inspection – Cub Cadet G730 User Manual

Page 29: Assembly

background image

27 G730

INPUT SHAFT

Refer to Figure 19

Disassembly

1. Requires removal of all items beginning on

page 22.

2. Remove the retaining ring (57).
3. Remove the lip seal (56) and discard.
4. Remove the washer (55) and the pump shaft

assembly (52–53).

NOTE: To assist in the removal of the pump

shaft, lightly tap (using a neoprene

head hammer) the shaft from the

charge pump side of housing. Care

should be taken not to damage the

shaft or gerotor running surface.

Remove the bearing from pump shaft

only if worn or damaged.

5. Remove the wire ring retainer (54) and the

bearing (53) from the pump shaft (52).

Inspection

1. Inspect the bearing and input shaft for

wear or damage. Inspect the splines on

the shaft for possible damage.

Replace if necessary.

Figure 19, Input Shaft

Assembly

1. Reassemble all parts in the reverse order

of disassembly.

57

56

55

54

53

52