COP-USA CD66MK-HW User Manual
Page 18

- 15 -
3.4 Protocol and the Default Baud Rate
The SW2 is used to set the protocol of communication and the baud rate used by the dome
camera. DIP-4 to DIP-1 of SW2 is used to select protocols and 16 different protocols can be selected
in maximum. Following table shows states of coding switches of protocols selected by the dome
camera.
Protocols
DIP status
Normal Baud Rate
DIP-1
DIP-2
DIP-3
DIP-4
DIP-5
DIP-6
B01
ON
OFF
OFF
OFF
OFF
ON
SAMSUNG-1
ON
OFF
OFF
OFF
OFF
ON
Santachi
OFF
ON
OFF
OFF
OFF
ON
PELCO-P/D
ON
ON
OFF
OFF
OFF
OFF
PELCO-MK
OFF
OFF
ON
OFF
OFF
OFF
PANASONIC
ON
OFF
ON
OFF
OFF
ON
Longcomity
OFF
ON
ON
OFF
OFF
ON
HUNDA600
ON
ON
ON
OFF
OFF
ON
LILIN
OFF
OFF
OFF
ON
OFF
ON
VICON
ON
OFF
OFF
ON
ON
OFF
MOLYNX
OFF
ON
OFF
ON
OFF
ON
KALATEL
ON
ON
OFF
ON
ON
OFF
VCL
OFF
OFF
ON
ON
OFF
ON
SAMSUNG-2
ON
OFF
ON
ON
OFF
ON
ALEC
OFF
ON
ON
ON
OFF
ON
Ultrak
ON
ON
ON
ON
OFF
ON
Table 2