7-1. PC-mode
1. The numbers other than 1-5 on this switch are
not used.
2. Do not duplicate numbers with other
WV-CU300/WJ-PC10.
7-2. Extension-mode
1, Set this switch to number 0 for every WJ-PCi 0.
8. Data Clock Switch (DATA CLOCK SND/RCV)
When the data clock is supplied to this Data
Input/Output Connector(9), turn this switch to the
RCV position. And when the data clock is sent out
from this connector, turn this switch to the SND
position.
Note:
When the system is separated in some sites
connecting with the modem units and so on,
the SND-RCV connection should be made in
each site. In each site, only one unit should be
set as the SND unit and the other units should
be set as the RCV unit.
9.
Data Input/Output Connector (DATA IN/OUT 1 /2)
These connectors send out or accept the system
data to/from other system components in System
300. Also the data clock signal is either sent out or
received through these connectors.
10. 12VDC Input Terminals (DC 12V IN)
Supply 12VDC power to this terminals.
Caution:
Use class 2 power supply only.