beautypg.com

Panasonic WJ-PC10 User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

1. SW3 ; Selection of the baud rate of RS-232C signal,

Turn on one of 6 switches.

No.1

1200 bps

No.2

2400 bps

No.3

4800 bps

No.4

9600 bps (Factory set up)

No.5

19200 bps

No.6

38400 bps

SW4 : Selection of the function.

The factory preset switch position is OFF for all

switches.

Select ON or OFF position according to your system.

2-1. Operation mode : PC-mode

SW No.

Function

Switch position

No.1

Parity bit

ON:None

OFF:Yes

No.2

Parity mode

ON:EVEN

OFFODD

No-3

Stop bit

ON:2bit

OFF:1 bit

No,4

Data bit

ON:8bit

OFF;7bit

No.5

Alarm selection

ON:stop

OFF:release

No.6

Main/Sub selection

Should be OFF position

No.7

DTE/DCE selection

ON:DTE

OFFiDCE

No.0

Operation mode

Should be OFF position

Note:

When the Alarm switch (No.5) is turned on,

the alarm signal to the RS-232C line can

be

stopped.

However,

the

alarm

signal

can be confirmed by operating computer via

WJ-PC10.

2-2. Operation mode : Extension-mode

Function

Parity bit

Parity mode

Stop bit

Data bit

Xon/Xoif control

Main/Sub selection

DTE/DCE selection

Operation mode

Switch position

Should be OFF position

Should be OFF position

Should be OFF position

Should be OFF position

Should be OFF position

ON:Sub

OFF:Main

ON:DTE

OFF:DCE

Should be ON position

Note on Extension-mode:The Modem units should

be set as follows.

Parity

Stop bit

Data bit

Xon/Xotf

None

1 bit

8 bits

Not used

- 8