beautypg.com

System error table – Panasonic WJ-PC10 User Manual

Page 20

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

SYSTEM ERROR TABLE

LED indication

Cause

Trouble points

SYS DATA RX

No data sync

Duplicated data sync

• Data Clock Switch on all units are set to

RCV position,

# Broken system data line with ’’RCV"

WJ-PCIO.

• Duplicated "SND" position of WJ-PCiO with

other units.

SYS DATA TX

Wrong Controller Unit No,

• Controller Unit No. is set either 0, 6, 7, 8 or

9 in PC-mode.

• Controller Unit No. is set other than 0 in

Extension-mode.

Duplicated Controller Unit No.

• Controller Unit No, duplicated with

WJ-PCiO in PC-mode.

RS-232 RX

75i7 termination error

• Broken or non-termination of system data

line with"SND" WJ-PCiO.

RS-232 TX

WJ-MP404 site error in PC-mode

• Duplicated "SND’' position of WJ-PCiO with

WJ-MP404.

• Duplicated "Unit No." of system components.

• Broken or non-termination of system data

line.

- 18 -