37

+12V

It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).

Earth cable.

485 A/B

485 communication port. They are used to control devices such as
decoder.

T+,T-,R+,R-

They are four-wire double duplex RS485 port
T+ T-: output wire
R+ R-: input wire

3.8.2 Alarm Input Port

Please refer to the following sheet for more information.
z

Grounding alarm inputs. Normal open or Normal close type)

z

Please parallel connect COM end and GND end of the alarm detector (Provide

external power to the alarm detector).

z

Please parallel connect the Ground of the DVR and the ground of the alarm detector.

z

Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)

z

Use the same ground with that of DVR if you use external power to the alarm device.

Figure 3-7

3.8.3 Alarm Output Port

z

Provide external power to external alarm device.

z

To avoid overloading, please read the following relay parameters sheet carefully.

z

RS485 A/B cable is for the A/B cable of the PTZ decoder.

z

T+,T-,R+,R- are four-wire double duplex RS485 port.

T+ T-: output wire
R+ R-: input wire

Relay Specification

Model:

JRC-27F

Material of the
touch

Silver

Rating

Rated switch capacity

30VDC 2A, 125VAC 1A