CANOGA PERKINS L351 10/100BASE Media Converter User Manual
Page 65

EdgeAccess Universal Chassis System
L351 10/100BASE Media Converter
4-41
If the firmware on the L351 is outdated, you need to upgrade it. If the L351 is in a chassis or 1030
enclosure within a domain with a DMM, go to the User Manual for the DMM and use that procedure
to install the new software. If the L351 is in a Model 1020, follow these steps:
1. TFTP server should be open and running.
2. From the Main Menu, type 7, Software Upgrade, and press
3. At the Software Upgrade menu, type 4, Get New File with TFTP, and press
4. At the prompts, type the IP address for the TFTP server and the File Name.
5. At the prompt, type Y to transfer the file and start the upgrade.
To upgrade a remote unit to the same version of software, follow these steps:
1. From the Main Menu, type 7, Software Upgrade, and press
2. At the Software Upgrade menu, type 3, Copy Software from Source unit to Destination unit,
and press
3. At the prompt, select the Source, which is the inactive bank for the local module, then select
the Destination, which is the inactive bank for the remote module, and press
upgrade runs automatically.
To run the new software, swap banks, and reset the module, follow these steps:
1. From the Main Menu, type 7, Software Upgrade, and press
2. At the Software Upgrade menu, type 2, Swap Bank, press
column, and press
3. Type 2, Swap Bank, check that the Local column is highlighted, and press
modules reset and start using the new firmware.