Instruction manual, Controls, Installation – Pilz PSEN op1.2 Emitter M12 User Manual
Page 2: Connections, Dimensions, Technical data, Setting, Test function (psen op1.2), Cable version

PSEN op1.1, PSEN op1.2,
PSEN op1.3
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (PSEN op1.3/PSEN op1.1)
The yellow LED ON indicates that the N.O. (normally open) output
status is closed.
STABILITY LED (PSEN op1.3/PSEN op1.1)
The green LED ON indicates that the received signal has a reserve
greater than 30% compared to the output switching value.
POWER ON LED (PSEN op1.2)
The green LED indicates that the sensor is operating.
TRIMMER (PSEN op1.3/PSEN op1.1)
The trimmer can be used to adjust sensitivity; the operating distance
increases turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270° by a mechanical stop.
Do not apply excessive torque when adjusting (max 40 Nmm).
INSTALLATION
The sensor can be positioned by
means of the three housing’s holes
using two screws (M4x25 or longer, 1.5
Nm maximum tightening torque) with
washers.
Various orientable fixing brackets to
ease the sensor positioning are
available (please refer to the
accessories listed in the catalogue).
The operating distance is measured
from the front surface of the sensor
optics.
The M12 connector can be oriented at two different positions using the
specific fastening spring and rotating the block of 180°.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
PSEN op1.3/PSEN op1.1
+
10 … 30 Vdc
N.C. OUTPUT
BROWN
1
WHITE
2
BLACK
4
BLUE
3
N.O. OUTPUT
0 V
PSEN op1.2
+
10 … 30 Vdc
TEST +
BROWN
1
WHITE
2
BLACK
4
BLUE
3
TEST -
0 V
M12 CONNECTOR
2
3
1
4
DIMENSIONS
TRIMMER
CABLE VERSION
Ш4
15
Ш15
M12
16
26
.5
OUTPUT LED
POWER ON LED (PSEN op1.2)
42
50
14
11 6
42
50
2
18x4
5°
23.6
STABILITY LED
mm
TECHNICAL DATA
Power supply:
10 … 30 Vdc (limit values)
Ripple:
2 Vpp max.
Current consumption
(output current excluded):
35 mA max.
Outputs:
PNP or NPN; 30 Vcc max. (short-circuit protection)
Output current:
100 mA max.
Output saturation voltage:
≤ 2 V
Response time:
0.5 ms mod. PSEN op1.3; 1 ms mod. PSEN op1.1
Switching frequency:
1 kHz mod. PSEN op1.3; 500 Hz max. mod. PSEN op1.1
Indicators:
OUTPUT LED (YELLOW)
STABILITY LED (GREEN) (mod. PSEN op1.3/ PSEN op1.1)
POWER ON LED (GREEN) (mod. PSEN op1.2)
Setting:
sensitivity trimmer (mod. PSEN op1.3/ PSEN op1.1)
Operating temperature:
-25 … 55 °C
Storage temperature:
-25 … 70 °C
Electrical shock protection:
Class 2
Operating distance (typical values):
PSEN op1.3: 0.1…6 m on Reflector
PSEN op1.3/ PSEN op1.2: 0…20 m
Emission type:
RED (660 nm) mod. PSEN op1.3; INFRARED (880 nm) mod. PSEN op1.2
Ambient light rejection:
according to EN 60947-5-2
Vibrations:
0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Housing material:
ABS
Lens material:
PMMA window, polycarbonate lens
Mechanical protection:
IP67
Connections:
2 m cable
∅ 4 mm / M12-4 pole connector
Weight:
90 g. max. cable vers. / 40 g. max. connector vers.
SETTING
Setting of PSEN op1.3
Position the sensor and reflector aligned on opposite sides.
Turn the sensitivity trimmer to the maximum position.
Moving the sensor both vertically and horizontally, determine the power
on and off points of the yellow LED (OUT) and then mount the sensor in
the middle of the points defined.
Optimum operation is obtained when the green LED is ON and the
yellow LED is OFF.
If necessary reduce sensitivity in order to detect very small targets. In
order to improve alignment, repeat the procedure detailed above whilst
progressively reducing the sensitivity.
Setting of PSEN op1.1 and PSEN op1.2
Position the sensors aligned on opposite sides.
Turn the sensitivity trimmer to maximum: moving the sensor both
vertically and horizontally, determine the power on and off points of the
yellow LED (OUT) and then mount the sensor in the middle of the points
defined. Optimum operation is obtained when the green LED is ON and
the yellow LED is OFF.
If necessary, reduce sensitivity using the trimmer, in order to detect very
small targets. In order to improve alignment, repeat the procedure
detailed above whilst progressively reducing the sensitivity.
TEST FUNCTION (PSEN op1.2)
The TEST+ and TEST- inputs can be used to inhibit the emitter and
verify that the system is correctly operating.
The receiver output should switch when the test is activated while the
beam is uninterrupted.
The inputs activating voltage range is 10 … 30 Vdc, whilst respecting the
polarity.
The emission is switched off connecting TEST+ to Vdc and TEST- to
0V.
A
Pilz Ges.m.b.H., 01 7986263-0, Fax: 01 7986264, E-Mail:
AUS
Pilz Australia Industrial Automation LP., 03
95446300, Fax: 0395446311, E-Mail: [email protected]
B L
Pilz
Belgium, 09 3217570, Fax: 09 3217571, E-Mail: [email protected]
BR
Pilz
do Brasil Sistemas Eletr¶nicosIndustriais Ltda., 11 4337-1241, Fax: 11
4337-1242, E-Mail: [email protected]
CH
Pilz lndustrieelektronik
GmbH, 062 88979-30, Fax: 062 88979-40,E-Mail: [email protected]
DK
Pilz Skandinavien K/S, 74436332, Fax: 74436342, E-Mail: [email protected]
E
Pilz lndustrieelektronik S.L., 938497433, Fax:938497544, E-Mail:
F
Pilz France Electronic, 03 88104000, Fax: 03
88108000, E-Mail: [email protected]
FIN
Pilz Skandinavien K/S, 09
27093700, Fax: 09 27093709, E-Mail: [email protected]
GB
Pilz
Automation Technology, 01536 460766, Fax: 01536 460866, E-Mail:
[email protected]
I
Pilz ltalia Srl, 031 789511, Fax: 031 789555, E-
Mail: [email protected]
IRL
Pilz Ireland Industrial Automation, 021 4346535,
Fax: 021 4804994, E-Mail:[email protected]
J
Pilz Japan Co., Ltd., 045
471-2281, Fax: 045 471-2283, E-Mail: [email protected]
MEX
Pilz de
Mexico, S. de R.L. de C.V., 55 5572 1300,Fax: 55 5572 4194, E-Mail:
[email protected]
NL
Pilz Nederland, 0347 320477, Fax: 0347
320485, E-Mail: [email protected]
NZ
Pilz New Zealand, 09-6345350, Fax:
09-6345350, E-Mail: [email protected]
P
Pilz Industrieelektronik
S.L., 229407594, Fax: 229407595, E-Mail: [email protected]
PRC
PilzChina Representative Office, 021 62493031, Fax: 021 62493036, E-
Mail: [email protected]
ROK
Pilz Korea Office, 031 8159541, Fax:
031 8159542,E-Mail: [email protected]
SE
Pilz Skandinavien K/S,
0300 13990, Fax: 0300 30740, E-Mail: [email protected]
TR
Pilz
Elektronik Güvenlik Ürünleri veHizmetleri Tic. Ltd. ©Sti., 0224 2360180,
Fax: 0224 2360184, E-Mail: [email protected]
USA
Pilz Automation
Safety L.P., 734 354-0272, Fax: 734 354-3355,E-Mail:
[email protected]
www
www.pilz.com
D
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Stra
βe 2,
73760 Ostfildern, Deutschland,
+49 711 3409-0, Fax: +49 711 3409-133, E-Mail: [email protected]
826002350 rev.00