Installation and operating instructions, Electrical connection, Mechanical data – Pilz PSEN me1.21S / 1AR User Manual
Page 3: Solenoid
Installation and Operating Instructions
Date of issue: 22.02.2006 / Page 9 of 12
Document : 0800000458 / Version: 01 / 2196-06
Pilz GmbH & Co. KG, Sichere Automation, Felix-Wankel-Straße 2, D-73760 Ostfildern, Deutschland
Phone: +49 711 3409-0, Fax: +49 711 3409-133, E-Mail: [email protected], www.pilz.com
Template : 0850174292 Orig. 2
Mechanical data
Enclosure
thermoplastic glass fibre reinforced
Mechanical life
1 million switching cycles at
(UL94-VO)
max. 600 cycles/hour
Cover
thermoplastic glass fibre reinforced
Mounting
4 M 5 screws
ISO1207
(UL94-VO)
ISO
4762
Actuator head
thermoplastic glass fibre reinforced
Tightening torque (max.)
M= 2 Nm
and Zn-GD
Conductor cross-section
Separate actuator
St/PA / Zn-GD
Termination
cage clamp
1.5 mm² flex max.
Ambient air temperature
-25 °C to +70 °C, -13 °F to +158 °F
Cable entry
3 (M20X1.5)
Locking force F
Zh
max. 1500 N
Mounting
position
any orientation
According to GS-ET-19
Weight
approx. 0.3 kg (w/o actuator)
Actuating force
27 N min.
Actuating speed
V=0.5 m/s max.
Electrical connection
The electrical connection shall only be carried out
by trained and qualified personnel!
I Release snap-shut terminal lid with a screwdriver
II Screw cable gland into the chosen entry, this will
‘break-out’ blind hole, remove plastic disk.
Connecting to cage clamp terminals:
1) Insert screwdriver (blade width 2.5 mm) in
lower opening
2) Turn 45°
3) Insert flex. cable in upper opening
(Max. 1.5 mm
2
cross-section)
remove screwdriver.
III Snap terminal chamber lid shut
Electrical data
Protection class
IP 67 acc. to IEC 60529
Approvals
see label on housing
Switch function
4 slow-action contacts max.
BG (GS-ET-19) (applied for)
Rated insulation voltage
U
i
250V
cCSAus B300, R300 (applied for)
Utilization category
AC 15 230V/2.5 A
Conventional thermal current
I
the
2.5 A
Standards
VDE 0660 T100, EN 60947-1
Max. making current (4 contacts)
10 A
VDE 0660 T200, EN 60947-5-1
Type of short-circuit protection
4 A gl
IEC 60947-5-1 GS-ET-19
Solenoid
Actuating cycles permanent
600 / hour
Solenoid power consumption PSEN me1
15 VA (0.5 s)
inrush
Operating voltage
PSEN me1
24 V AC/DC
≤ 1.4 VA (24 V) continuous
PSEN
me1.1
24 V DC +24/110/230 V AC
PSEN me1.1
56 VA (0.2 s)
inrush
ON period
100 % duty cycle (to E1, E2)
1.1 VA
continuous
Temperature class
B (130 °C), (266 °F)
45
I
I
2
1