beautypg.com

Caution, Spider alert – Char-Broil 4539937 User Manual

Page 9

background image

9

CAUTION

SPIDER AND WEBS

INSIDE BURNER TUBE

5. If “growing”

If leaks cannot

be stopped do not try to repair.

6.

bubbles appear, there is a leak. Close gas

source immediately and tighten connection.

Call for replacement parts.

Order new parts by giving the serial, model number and name
of items needed to the Grill Service Center at

.

Always close gas source after performing leak test.

1-888-430-7870

General Grill Cleaning

Do not mistake brown or black accumulation of grease and
smoke for paint. Interiors of gas grills are not painted at the
factory

. Apply a strong solution

of detergent and water or use a grill cleaner with scrub brush on
insides of grill lid and bottom. Rinse and allow to completely air
dry.

(and should never be painted)

Do not apply a caustic grill/oven cleaner to painted

surfaces.

SPIDER ALERT!

SPIDER WEBS

INSIDE VENTURI

VALVE

CONTROL PANEL

If you notice that your grill is getting hard to light or that the
flame isn’t as strong as it should be, take the time to check and
clean the venturi’s.

In some areas of the country, spiders or small insects have been
known to create “flashback” problems. The spiders spin webs, build
nests and lay eggs in the grill’s venturi tubes(s) obstructing the flow of
gas to the burner. The backed-up gas can ignite in the venturi behind
the control panel. This is known as a flashback and it can damage
your grill and even cause injury.

To prevent flashbacks and ensure good performance the burner and
venturi assembly should be removed from the grill and cleaned before
use whenever the grill has been idle for an extended period.

Normal
Hose

Kinked
Hose

Leak Testing

1. Turn all grill control knobs to OFF.

2.

3.

Correct before proceeding

4.

Be sure gas hose is tightly connected to gas source.

Completely open gas source. If you hear a

, turn

gas off immediately. There is a major leak at the connection.

.

Brush soapy solution onto area circled below.

rushing sound

Burner Flame Check

Turning Grill Off

Ignitor Check

Valve Check

Hose Check

OFF

IMPORTANT: Make sure gas is OFF at LP cylinder before
checking valves.

OFF

LOW

OFF

Remove cooking grates and troughs. Light burners, rotate knobs
from to . You should see a smaller flame in
position than seen on . Perform burner flame check on side
burner, also. Always check flame prior to each use. If only low
flame is seen refer to “Sudden drop or low flame” in the

of your grill manual.

Turn all knobs to

position. Turn LP cylinder off by

turning hand-wheel clockwise to a full stop.

Turn Gas OFF at LP cylinder. Press and hold electronic ignitor
button. “Click” should be heard and spark seen each time
between collector box or burner and electrode. See

in your grill manual if no click or spark

Knobs lock in

position. To check valves,

first push in knobs and release, knobs should spring back. If
knobs do not spring back, replace valve assembly before using
grill. Turn knobs to

position then turn back to

position.

Valves should turn smoothly.

Before each use, check to see if hoses are cut or worn. Replace
damaged hoses before using grill. Use only valve/hose/regulator
specified by manufacturer.

Troubleshooting Section

“Troubleshooting”

.