beautypg.com

Main burner conversion (cont.) – Char-Broil 4539937 User Manual

Page 16

background image

Main Burner Conversion (Cont.)

7

- Using a #2 Phillips screwdriver, reinstall the two #8x3/8” screws that attach the Orifice Holder to the burner flange. Repeat for each Orifice

Holder. DO NOT over-tighten the Orifice Holder screws.

Re-install 2 #8x3/8”
screws into
Burner Flange.

Orifice

Holder

Burner

Flange

- Pull the Burner Control Knobs off of Valve Stems.

- Remove screws and washers that secure each Bezel to the Control Panel. Remove Bezels. Save removed Bezels for converting back to LP

Tank Gas.

- Install new Natural Gas Bezels provided with Kit (see illustration below) in place of old Bezels onto Control Panel, and secure using previously

removed screws and washers. Assure proper alignment with control knob before fully tightening.

- Press Control Knobs back onto Valve Stems. Make adjustments needed to Bezels for free movement of Control Knobs.

Replace Main Burner Bezels and Control Knobs

NOTE: REPLACE ONE BEZEL AT A TIME. DO NOT REMOVE ALL THE BEZELS AT THE SAME TIME.

Note: New bezels will change the rotation

for the control knob to properly control ignition and flames for your grill.

8

Natural Gas Bezel

80004350

NOTE: Replace only one

bezel at a time!

16

Valve

Stem

Bezel

Main Burner

Control Knob

Screw

Screw