Welch Allyn Vital Signs Monitor, Mounting Accessories - User Manual User Manual
Welch Allyn Equipment

Table of Contents
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Set Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Operating Procedure/Focusing Optics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Green Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Transportation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Set Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Operating Procedure/Focusing Optics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Green Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Halogen Lamp Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Fuse Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Document Outline
- Warnings and Cautions 1
- Overhead Zoom Colposcope 2
- Upright Post Zoom Colposcope 6
- Maintenance 9
- Replacement Parts 10
- Warranty 10
- Service 10
- Overhead Zoom Colposcope
- Upright Post Zoom Colposcope
- Preface
- Purpose of the Manual
- Warnings and Cautions
- Overhead Zoom Colposcope
- Model 88520
- Unpacking
- Shipping Carton 1:
- Shipping Carton 2:
- Set Up
- 1. Carefully remove the contents from both shipping cartons. Do not damage the colposcope head.
- 2. Lock all wheels on the roller base assembly.
- 3. Insert the post into the base assembly with the light source upright. Push until the post feel...
- 4. Tilt the base assembly and post sideways, do not rest the assembly on the light source.
- 5. Slide the post collar onto the bottom of the post making sure that the collar is flush against...
- 6. Tip the light source post and base assembly back into an upright position. Insert the arm pivo...
- 7. Place the fiber optic cable adapter onto the fiber optic cable and tighten the set screw (if t...
- 8. Plug the fiber optic light bundle (attached to the colposcope head) into the light source.
- 9. Carefully insert the scope head and into the focus stand arm. Firmly push into place and tight...
- 10. Firmly place the green filter assembly on the front of the colposcope head. Verify the lens i...
- 11. Plug the fiber optic cable into the Green Filter assembly (if not already asembled). Tighten ...
- 12. Remove the protective caps from the colposcope head and replace with the provided oculars. Ad...
- 13. Plug the power cord into the bottom of the light source. If desired, secure the light source ...
- 14. Plug the Overhead Colposcope Zoom unit into a hospital grade outlet.
- Set Up
- Operating Procedure/Focusing Optics
- 1. Twist the manual locking handle on the overhead arm to the left so that desired vertical align...
- 2. Rotate the illumination intensity knob clockwise to “ON” position and adjust to desired light ...
- 3. Adjust the coloscope head to desired working position using the tilt handle.
- 4. Rotate the colposcope fine focus adjustment clockwise or counterclockwise until the approximat...
- 5. Set the oculars to zero by rotating the diopter rings. Align dots on ocular and sleeve.
- 6. Rotate the Zoom Control Knob to minimum magnification.
- 7. Adjust the oculars to match the interpupillary distance so that both circular views are brough...
- 8. Identify your dominant eye and close the inferior eye.
- 9. While viewing through the “dominant” eyepiece, push the colposcope towards or away from a prin...
- 10. View through both eyepieces and rotate the zoom control from maximum to minimum magnification...
- 11. Adjust the fine focus as necessary to compensate for patient movement during the exam.
- Green Filter
- CAUTION
- Transportation
- Specifications
- Upright Post Zoom Colposcope
- Unpacking
- Shipping Carton 1:
- Shipping Carton 2:
- Set Up
- 1. Carefully remove the contents from both shipping cartons. Do not damage the colposcope head.
- 2. Lock all wheels on the roller base assembly.
- 3. Insert the post into the base assembly and push until the post feels tight.
- 4. Insert colposcope head shaft into upper post collar.
- 5. Place the fiber optic cable adapter onto the fiber optic cable and tighten the set screw.
- 6. Plug the fiber optic light bundle (attached to the colposcope head) into the light source.
- 7. Attach the power cord to the bottom of the light source.
- 8. Remove the protective caps from the colposcope head and replace with the 20X oculars. Add the ...
- 9. Plug unit into a hospital grade outlet.
- Operating Procedure/Focusing Optics
- 1. Set the post assembly to the desired height and then tighten the adjustment knob to set it in ...
- 2. Rotate the illumination intensity knob clockwise to “ON” position and adjust to desired light ...
- 3. Rotate the colposcope fine focus adjustment clockwise or counterclockwise until the approximat...
- 4. Adjust scope to desired working position by pushing or pulling the tilt handle.
- 5. Set the oculars to zero by rotating the diopter rings. Align dots on ocular and sleeve.
- 6. Rotate the Zoom Control Knob to minimum magnification.
- 7. Adjust the oculars to match the interpupillary distance so that both circular views are brough...
- 8. Identify your dominant eye and close the inferior eye.
- 9. While viewing through the “dominant” eyepiece, push the colposcope towards or away from a prin...
- 10. View through both eyepieces and rotate the zoom control from maximum to minimum magnification...
- 11. Adjust the fine focus as necessary to compensate for patient movement during the exam.
- Green Filter
- Set Up
- CAUTION
- Specifications
- Maintenance
- 1. Cleaning the lens: To clean the lens surface, remove dust using a soft brush or gauze. For rem...
- 2. Cleaning of plastic parts: Avoid the use of any organic solvent (i.e. thinner, ether, alcohol,...
- 3. Never attempt to dismantle the instrument. Contact Welch Allyn Technical Services if service i...
- 4. When not in use: Cover the instrument with the dust cover provided and store the colposcope in...
- Halogen Lamp Replacement
- 1. Turn ON/OFF switch to “OFF” position and unplug the unit from the power receptacle.
- 2. Open the front cover of the light source (lamp access cover) by pushing the button and simulta...
- 3. Grasp lamp by the socket and pull straight out of the light source.
- 4. Remove the lamp assembly from the socket.
- 5. Replace the lamp with Welch Allyn part number 04050.
- 6. Securely replace lamp assembly into light source.
- 7. Replace the cover by holding the cover tight against the light source and slide up.
- Fuse Replacement
- 1. Turn the ON/OFF switch to the “OFF” position and unplug the power cord from the wall outlet.
- 2. Remove the power cord from the bottom of the light source. The fuse drawer is located directly...
- 3. Replacement fuses are available from Welch Allyn, part number 88428. The fuse is a 5 x 20 mm 2...
- 4. Replace the fuse drawer into the light source until it snaps.
- 5. Plug the power cord into a hospital-grade wall outlet.