Troubleshooting guide – Vintage Cellars CC-CX8800 User Manual
Page 27

www.cellarcool.com | Page 25
TROUBLESHOOTING GUIDE
Solution
Unit should be level in wall to prevent leaking
Check drain line to make sure water can flow freely.
Disconnect Drain and clear out.
Fix drain line so there is a downward slope from the
unit to the drain.
Melt ice with blow drier. Soak up with a towel.
Solution
Make sure fans are unobstructed; clean evaporator if necessary
Compressor may have overheated. Shut unit off for 1 hour to
allow compressor to cool. Turn back on and check for cooler air
flow out. If compressor runs, check for and clean condenser coil
as possible cause of compressor overheating. If problem repeats,
call Technical Support (855) 235-5271
Call Technical Support at (855) 235-5271
Solution
Call Technical Support at (855) 235-5271
Compressor may have overheated. Shut unit off for 1 hour to
allow compressor to cool. Turn back on and check for cooler air
flow out. If compressor runs, check for and clean condenser coil
as possible cause of compressor overheating. If problem repeats,
call Technical Support.
Solution
Call Technical Support at (855) 235-5271
Call Technical Support at (855) 235-5271
Solution
Call Technical Support at (855) 235-5271
Solution
Install proper vapor barrier
Unit leaks water
Possible Cause
Unit is not level
Drain line clogged or kinked
Drain is clogged preventing water from escaping
Drain line does not have a downward slope
Coil is iced causing excess condensation.
Unit runs but does not cool
Possible Cause
Lack of air flow/heat exhaust (outer room)
Fans run but compressor does not.
Unit undersized
Evaporator fan runs but compressor does not
Possible Cause
Compressor and/or starting components faulty
Fans run but compressor does not.
Compressor runs; evaporator fan does not
Possible Cause
Faulty fan motor
Faulty fan relay
Compressor short cycles
Possible Cause
Compressor and /or starting components faulty
Humidity in cellar too high
Possible Cause
Cellar vapor barrier not sufficient