Alarm

The Alarm symbol is shown when the unit encounters an issue that needs attention, the dis-

played alarm codes are explained below. The alarm code will remain displayed until corrected.

Alarm Codes

CPSM (Customer Preference Selection Mode)

Message

Cause

Solution

“E1”

Faulty Air Sensing Probe

Contact Customer Service

“AH1”

The air probe is sensing a

temperature that is 10° above

the set point

1. Allow time for the wine to reach the desired temperature.

2. Make sure all windows and doors are closed and have a proper seal.

3. Follow the procedures in the pre-installation instructions to test the unit for proper

cooling.

“AL1”

The air probe is sensing a

temperature that is 10° below

the set point

1. Make sure unit is not in cooling mode. (the snowflake symbol will not be lit)

2. Add heat to the room until the wine reaches the desired temperature.

Press and hold the set button for approximately 5 seconds to enter the CPSM menu.

Use the down arrow to access the following parameters.

PA2

No adjustable settings in this parameter.

tab

No adjustable settings in this parameter.

Rel

No adjustable settings in this parameter.

LOC Change this parameter from “n” to “y” to lock the keyboard from changes to the set point.

CA1 Change the value to increase or decrease the temperature reading of the air sensor. (This process

re-calibrates to the sensor.) Increasing the value by 1 means an increase in the temperature

reading by 1 degree. This parameter can be adjusted +- 12 degrees. If needed: Adjust this setting

to match your temperature sensor located inside of the cellar.