Troubleshooting guide – Vintage Cellars CC-CX8800 User Manual

Page 26

background image

Page 24 | 1-855-235-5271

CX 012014

TROUBLESHOOTING GUIDE

Unit has ice forming on the evaporator

Possible Cause

Evaporator filter and/or coil are dirty.

There is something blocking the supply and or return air

One or both evaporator fans are not turning on.

The temperature of the room, the unit is exhausting to,

has dropped below 50°

The unit has not gone through its anti-frost sequence, yet.

If unit continues to ice.

Unit does not run/power up

Possible Cause

Unit is not plugged in

No power to outlet

Line voltage is incorrect rating for unit

Room at set point

Thermostat not calling for cooling

Faulty thermostat or wiring

Cellar Temperature is to Warm

Possible Cause

The temperature or the room unit is exhausting to has

exceeded 85°

The unit is undersized for the room.

There is something blocking the supply and/or return air,

on evaporator or condenser side of the unit

Unit is mounted too low in the cellar

One or more of the fans is not turning on.

Compressor is not turning on.

Compressor keeps cycling on overload

Poor seal around door.

Controller set too high

Evaporator coil is frosted or iced up

Solution

Clean filter and coil with a vacuum.

If coil is very dirty, use a small hand spray with a small amount of liquid

dish washer detergent. Spray coil, let set for 5 min, then flush with fresh

water.
Remove blockage
Call a service tech to troubleshoot
Raise the temperature of the exhaust room


Check for ice in the depth of the coil. Melt with blow drier until coil is

warm to the touch. Soak up water with a towel.
Observe ice formation pattern. If only part way up the coil face, unit could
be low on refrigerant. If so, call Technical Support at (855) 235-5271

Solution

Make sure the unit is plugged into an outlet
Contact an Electrician
Check line voltage to make sure there is 115v/15amp
Lower set point
Lower set point
Call Technical Support at (855) 235-5271

Solution

Lower the temperature of the exhaust room.

Order correct size unit
Remove air flow obstruction

Re-Locate unit so the distance from the ceiling and top of the

unit is no more than 18”
Call Technical Support at (855) 235-5271
Call Technical Support at (855) 235-5271
Make sure all fans are working and there are no airflow obstruction.
Make sure there are no air gaps around the door. If door seal is dam-

aged, replace it.
Lower the set point.
Observe ice formation pattern. If only part way up the coil face, unit could
be low on refrigerant. If so, call Technical Support at

(855) 235-5271