beautypg.com

Possible defects: safety cushion, Repetitive inspections – Vetter SP 60 User Manual

Page 17

background image

Page 16/30

The safety cushion is operationally available after inspection and main-
tenance work has been carried out.

5.

Possible defects: safety cushion

Problem/Defect

Solution

The safety cushion does not align

itself correctly.

Check to see if parts of the safety

cushion have been caught up. In

this case, switch off the blower

and eliminate the defect immedi-

ately. Inflation can continue after

this has been done.
Check to see if the ventilation

openings are in perfect condi-

tion, including rubber rings. If

necessary align the rubber rings

so that the ventilation openings

remain closed.
Check to see if the blower is set

to maximum power, correct this if

necessary.

The hoses are bent.

Switch off the blower and realign

blower and hoses.

Possible defect: blower

Ramfan: Refer to the operating instructions for the blower from Page 27
onwards
Leader: Refer to the operating instructions for the blower from Page 29
onwards

6.

Repetitive inspections

Safety cushions are only permitted to be repaired by the manufacturer.
Maintenance work is only permitted to be carried out by persons who
have undergone special training by the manufacturer in maintenance
and repair work and are authorized to do this by the manufacturer. In
addition to this, they must work in a maintenance shop authorized by
the manufacturer and have a knowledge of the safety and accident pre-
vention regulations.
The following come solely into consideration for safety cushion inspec-
tion:

for Annual Inspection

The specialist according to the preliminary remarks in GUV-G 9102.

for the Main Safety Inspection

The specialist according to the preliminary

remarks in GUV-G 9102 in addition to extra

training by the manufacturer or a trainer

authorized by the manufacturer.