Page 13/30
Note! It is possible that the person to be rescued jumps
into a safety cushion which has not been completely
erected because this is not completely recognizable
from above!
The head of operations must decide, before erecting,
whether the safety cushion should be erected at the
operational location or whether it should be erected at
a safe location and then transported to the operation lo-
cation.
4.2
Normal functions
Adjust the blower, connected to the safety cushion, to maximum
power and then switch on.
Note! The blower must always be driven at maximum po-
wer so that the safety cushion can be quickly reset and is
always filled permanently with sufficient air.
Insufficient air supply can negatively influence operati-
on. The rotary control is set to maximum power for this
purpose.
The safety cushion unfolds assisted by the operator and only has
to be positioned. Using the positioning loops, the safety cushion
is lifted for setting up purposes. The blowers should be simultane-
ously aligned by two persons depending on the cushion.
The safety cushion is set up within a maximum time of 80 seconds.
In doing this a check should be made to see if the vent openings,
including rubber rings, are in perfect condition.
Should parts get caught up during safety cushion set up then
switch off the blower immediately and eliminate the defect. After
this has been done continue filling.
The safety cushion is fully operational only when it has been fully
set up.
The maximum jump height is 60 m!
After the person has jumped and has climbed out of the cushion,
the cushion automatically realigns itself within a maximum of 20
seconds to its original shape.