Vetter safety cushion sp 60 – Vetter SP 60 User Manual
Page 16
Vetter Safety Cushion SP 60
Page 15/30
Maintenance
Maintenance on the safety cushion must be carried out
by the manufacturer.
After use without loading by a falling load:
9
Cleaning
9
Visual inspection by the user
After use with loading by a falling load or a person to be
rescued:
9
Cleaning
9
Visual and function inspections by specialists having additio-
nal training by the manufacturer
Blowers
Cleaning
Ramfan blower
Before cleaning, disconnect the blower from mains power. The
blower must be regularly cleaned with a biodegradable cleaning
solution in order to get rid of dust and dirt.
Never immerse the blower motor in liquid or directly spray it.
Do not use any solvents (e.g. MEK, Acetone) which contain chlo-
rinated hydrocarbons. (refer to the separate instructions for the
blower - Section 9).
Maintenance
Ramfan blower
Check to see if the blower is perfectly operational. Opening the
blower for maintenance reasons is only permitted to be done by
specialists.
Leader blower
Normal maintenance of the petrol motor, with respect to oil
change and oil inspection is sufficient.
After operation it is recommended that a visual inspection be
made of the ventilator fins for hairline cracks or any other forms
of damage. If any damage to the fin is detected then this must be
repaired by the manufacturer due to the fact that the ventilator
wheel has to be balanced after exchanging the damaged part.
Important! Inspect safety cushions and blowers for da-
mage according to inspection instructions.