Problem

Solution

Waste discharge stops or decreases dramatically.

Turn the pump switch to the Off position, and check for foreign matter
lodged in the inlet hose or pump.

Failure to clear a clog could cause damage to the pump, which will void
the warranty.

The pump operates, but no liquid is expelled.

Wiring may be connected incorrectly.

Pump may be clogged.

Check that the RV dump valves are open.

The motor will not run.

Make sure that the:

Pump is turned on.

RV battery is charged.

Circuit breaker/fuse is functioning.

Pump is receiving voltage.

The shaft does not turn when power is being supplied to the pump.

Turn the pump switch to the Off position.

Insert a flat head screwdriver into the small hole in the bottom of the
motor (this is the end of the pump shaft). Refer to Fig. 6.

Rotate the screwdriver clockwise 1/4 turn.

Turn the pump switch to the On position.

Small leaks occur around the hose connections.

Tighten the clamps.

The toggle switch feels limp when activated.

Replace the switch.

How do I disassemble the pump to check for an object lodged in the
pump?

Instructions for disassembling the pump are available online at
www.thetford.com or from Customer Service at 1-800-543-1219.
You should replace the seals any time the pump is disassembled.
Seal kits are not warrantable parts; however, they are available for
purchase directly from Customer Service.

The barbs on my Twist-On Sani-Con have cracked. How can this be
avoided?

Add additional supports to the body of the pump. If the Twist-On Sani-
Con system will be permanently installed, use a 4 in. (10.2 cm) worm
gear clamp to support the bayonet. Also, use a flexible metal support
strap to support the weight of the motor.

Insert a screwdriver into the

2.

screwdriver slot located on the bottom

of the motor (some models have an

access port cover that will need to be

removed to access the screwdriver

slot). Refer to Fig. 6.
Turn the screwdriver clockwise to

3.

loosen the impeller.

Inserte un destornillador en la ranura

2.

para destornillador situada al fondo de la
bomba (algunos modelos tienen una tapa
del orifi cio de acceso, que deberá quitarse
para poder acceder al orifi cio) (fi g. 6).

Gire el destornillador para afl ojar el impulsor.

3.

Insérez un tournevis dans l’encoche

2.

située sur le dessous de la pompe
(certains modèles ont un couvercle à
enlever pour y accéder). Voir la fi g. 6.

Tournez le tournevis pour dégager la turbine.

3.

Troubleshooting and FAQ/Dépannage et FAQ/Resolución de problemas

y preguntas frecuentes

Fig. 6

AR

T001

14

AR

T001

18

Maintenance, Con’t.

Mantenimiento, cont.

Entretien, suite

Box Mount Model
Modèle à boîtier
Modelo de montaje en caja

Twist-On Model
Modèle à raccord rotatif
Modelo de montaje enroscable