Error messages – Rice Lake TradeRoute HL Series - M2000 Scale User Manual
Page 44

40
should be completed by pressing key one followed by PRINT/SELECT followed 
by TARE. There are a total of 6 set points available on the M2000A. Each set 
point can be allocated to any of the 3 channels. This parameter will be used to 
enter the weight at which the set point will do its evaluation. This value is 
channel dependent as far as the lb/kg units are concerned. 
Error Messages
1 Invalid parameter number for calibration mode
2 Graduation size invalid 
3 Decimal Position Invalid 
4 Flag values must be 1 for ‘ON’ and 0 for ‘OFF’ 
5 Push to Zero Window must be 0-99 
6 Zero tracking must be 1-99 or 100, 200, 300. 
7 Only 1 will reset parameters 
8 Only 1 will reset span table 
9 Span exceeds maximum capacity or span to small 
10 IZSM value can be 1 for ON and 0 for OFF 
11 Test Weight units must be 0=lb or 1=kg. 
12 Motion settle time out of range 1-100 
13 Power on units may only be 0=lb, 1=kg. 
14 Invalid Time entry HH.MM.SS 
15 Invalid Date entry YY.MM.DD 
16 Motion value is out of range 
17 Press tare to increment span table, any other key invalid 
18 Press tare to decrement span table, any other key invalid 
19 Span table cannot be decremented passed 1 
20 Parameter memory write error, indicator requires service 
21 Parameter checksum error, Parameters have been lost. 
22 Program check fault, indicator requires service 
23 Invalid Serial Port speed setting. 
24 Invalid Serial Port Parity parameter 
25 Cannot increment Span Table any further 
26 Entered offset larger than Capacity 
27 Invalid String mode for com port 
28 Power on Zero warning 0=Off, 1=On 
29 Channel enable is 0=Off and 1=On 
30 Only 1 will set the deadload 
31 Sound Volume can be between 0-3 
32 Keypress feedback can be 0=OFF or 1=ON 
33 Invalid Com String mode parameter 
34 Invalid Com Port Interface value 
35 Scale must be at zero before entering a keyboard tare (see parameter 71) 
36 Scale not ready to print 
37 Channel 1 cannot be disabled 