3 deadloading the scale (scale zero), 4 spanning the indicator, 3 sealing the indicator – Rice Lake TradeRoute HL Series - M2000 Scale User Manual
Page 25: 1 electronic seal, 2 audit trail

21
5.2.3 Deadloading the Scale (scale zero)
Before the indicator can be calibrated the deadload or scale zero value must 
be obtained. Remove all test weights from the scale. Key parameter 12 
followed by the PRINT/SELECT key. The display will show ‘r’ for “reconfirm”. 
Press 1 followed by the TARE key to confirm to continue with deadloading 
the scale. The indicator will pause for a short duration and then display the 
deadload value in AD counts to the display. The indicator will then return 
back to weight display mode. The indicator can now be calibrated with a 
known test weight.
5.2.4 Spanning the indicator
Place a known test weight on the scale. Enter 13 followed by the 
PRINT/SELECT key. The display will briefly flash “1”. Shortly after, the display 
will freeze with the last displayed weight. Enter the value of your test weight 
followed by the TARE key. The indicator will immediately calibrate and 
return back to weight display mode. If the display shows “EEEEEE” then you 
have exceeded the scale capacity value set in parameter 4 and 8. If the display 
shows “AAAAAA” then you have exceeded the input analog range of the 
indicator. The output voltage from the load cells exceeds the input for the 
AD converter.
Once the proper weight is displayed, exit calibration mode by pressing 99 
followed by the PRINT/SELECT key.
5.3 Sealing the indicator
The M2000 is sealed electronically with a password. There is also provision 
for physical sealing on all products. The 42300 and 42300M have faceplate 
screws that accommodate a wire and lead seal. 
5.3.1 Electronic Seal
Passwords are 4 digit numbers. The factory default for the password is 1111,
which can be changed in calibration mode. To change or view the password 
in calibration mode use parameter 96. Enter a 4 digit password followed by 
the TARE key. Important note: if you forget your password you will not be 
able to enter calibration mode on the indicator. Contact the factory for 
assistance at 604-941-3474. 
5.3.2 Audit Trail
The M2000 is equipped with a Category 1 Audit Trail system. It is
important that the correct time and date be set, as this is saved as part of